Design and verification of a high-gradient and high-power 2nd harmonic cavity for the China Spallation Neutron Source upgrade project.
- Source :
-
Review of Scientific Instruments . Apr2023, Vol. 94 Issue 4, p1-15. 15p. - Publication Year :
- 2023
-
Abstract
- Here, we report our recent progress in the design, fluid thermodynamics simulation, and high-power test of the2nd harmonic cavity for the China Spallation Neutron Source Phase II. A high-performance and large-size magnetic alloy (MA) core was developed as the load material for the radiofrequency cavity to achieve a high gradient of 40 kV/m. The water-cooling structure and cooling efficiency were studied and improved through numerical analysis and thermal experiments. The long-term stability of the cavity, especially the waterproofness of the MA cores with high heat load, was verified by high power tests. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00346748
- Volume :
- 94
- Issue :
- 4
- Database :
- Academic Search Index
- Journal :
- Review of Scientific Instruments
- Publication Type :
- Academic Journal
- Accession number :
- 163419919
- Full Text :
- https://doi.org/10.1063/5.0141079