Back to Search Start Over

Salivary Detection of Zika Virus Infection Using ATR-FTIR Spectroscopy Coupled with Machine Learning Algorithms and Univariate Analysis: A Proof-of-Concept Animal Study.

Authors :
Oliveira, Stephanie Wutke
Cardoso-Sousa, Leia
Georjutti, Renata Pereira
Shimizu, Jacqueline Farinha
Silva, Suely
Caixeta, Douglas Carvalho
Guevara-Vega, Marco
Cunha, Thúlio Marquez
Carneiro, Murillo Guimarães
Goulart, Luiz Ricardo
Jardim, Ana Carolina Gomes
Sabino-Silva, Robinson
Source :
Diagnostics (2075-4418). Apr2023, Vol. 13 Issue 8, p1443. 16p.
Publication Year :
2023

Abstract

Zika virus (ZIKV) diagnosis is currently performed through an invasive, painful, and costly procedure using molecular biology. Consequently, the search for a non-invasive, more cost-effective, reagent-free, and sustainable method for ZIKV diagnosis is of great relevance. It is critical to prepare a global strategy for the next ZIKV outbreak given its devastating consequences, particularly in pregnant women. Attenuated total reflection–Fourier transform infrared (ATR-FTIR) spectroscopy has been used to discriminate systemic diseases using saliva; however, the salivary diagnostic application in viral diseases is unknown. To test this hypothesis, we intradermally challenged interferon-gamma gene knockout C57/BL6 mice with ZIKV (50 µL,105 FFU, n = 7) or vehicle (50 µL, n = 8). Saliva samples were collected on day three (due to the peak of viremia) and the spleen was also harvested. Changes in the salivary spectral profile were analyzed by Student's t test (p < 0.05), multivariate analysis, and the diagnostic capacity by ROC curve. ZIKV infection was confirmed by real-time PCR of the spleen sample. The infrared spectroscopy coupled with univariate analysis suggested the vibrational mode at 1547 cm−1 as a potential candidate to discriminate ZIKV and control salivary samples. Three PCs explained 93.2% of the cumulative variance in PCA analysis and the spectrochemical analysis with LDA achieved an accuracy of 93.3%, with a specificity of 87.5% and sensitivity of 100%. The LDA-SVM analysis showed 100% discrimination between both classes. Our results suggest that ATR-FTIR applied to saliva might have high accuracy in ZIKV diagnosis with potential as a non-invasive and cost-effective diagnostic tool. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20754418
Volume :
13
Issue :
8
Database :
Academic Search Index
Journal :
Diagnostics (2075-4418)
Publication Type :
Academic Journal
Accession number :
163382767
Full Text :
https://doi.org/10.3390/diagnostics13081443