Back to Search Start Over

Towards a simplified fluid-sensitive MRI protocol in small joints of the hand in early arthritis patients: reliability between modified Dixon and regular Gadolinium enhanced TSE fat saturated MRI-sequences.

Authors :
Boeren, Anna M. P.
Niemantsverdriet, Ellis
Verstappen, Marloes
Wouters, Fenne
Bloem, Johannes L.
Reijnierse, Monique
van der Helm-van Mil, Annette H. M.
Source :
Skeletal Radiology. Jun2023, Vol. 52 Issue 6, p1193-1202. 10p.
Publication Year :
2023

Abstract

Objective: MRI of small joints plays an important role in the early detection and early treatment of rheumatoid arthritis. Despite its sensitivity to demonstrate inflammation, clinical use is hampered by accessibility, long scan time, intravenous contrast, and consequent high costs. To improve the feasibility of MRI implementation in clinical practice, we introduce a modified Dixon sequence, which does not require contrast and reduces total acquisition time to 6 min. Because the reliability in relation to conventional MRI sequences is unknown, we determined this. Methods: In 29 consecutive early arthritis patients, coronal and axial T2-weighted modified Dixon acquisitions on 3.0 T MRI scanner were acquired from metacarpophalangeal 2–5 to the wrist, followed by the standard contrast-enhanced protocol on 1.5 T extremity MRI. Two readers scored osteitis, synovitis and tenosynovitis (summed as total MRI-inflammation), and erosions (all summed as total Rheumatoid Arthritis MRI Score (RAMRIS)). Intraclass correlation coefficients (ICCs) between readers, and comparing the two sequences, were studied. Spearman correlations were determined. Results: Performance between readers was good/excellent. Comparing modified Dixon and conventional sequences revealed good/excellent reliability: ICC for total MRI-inflammation score was 0.84 (95% CI:0.70–0.92), for erosions 0.90 (95% CI:0.79–0.96), and for the total RAMRIS score 0.88 (95% CI:0.77–0.94). The scores of total MRI-inflammation, total erosions, and total RAMRIS were highly correlated (ρ = 0.80, ρ = 0.81, ρ = 0.82, respectively). Conclusion: The modified Dixon protocol is reliable compared to the conventional MRI protocol, suggesting it is accurate to detect MRI inflammation. The good correlation may be the first step towards a patient-friendly, short and affordable MRI protocol, which can facilitate the implementation of MRI for early detection of inflammation in rheumatology practice. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03642348
Volume :
52
Issue :
6
Database :
Academic Search Index
Journal :
Skeletal Radiology
Publication Type :
Academic Journal
Accession number :
163255765
Full Text :
https://doi.org/10.1007/s00256-022-04238-8