Back to Search Start Over

Quantitative PET tracking of intra-articularly administered 89Zr-peptide-decorated nanoemulsions.

Authors :
Díez-Villares, Sandra
García-Varela, Lara
Antas, Soraya Groba-de
Caeiro, José Ramón
Carpintero-Fernandez, Paula
Mayán, María D.
Aguiar, Pablo
de la Fuente, María
Source :
Journal of Controlled Release. Apr2023, Vol. 356, p702-713. 12p.
Publication Year :
2023

Abstract

Intra-articular (IA) administration of drugs for the treatment of diseases such as rheumatoid arthritis, osteoarthritis and psoriatic arthritis is a common strategy; however, the rapid clearance from the synovial fluid restricts their effectivity due to the limited retention time. Drug Delivery Systems (DDS) are currently being developed to increase their joint retention time. This study compares the biodistribution and retention time of a senolytic peptide (PEP), with potential application in osteoarthritis disease, and this senolytic peptide encapsulated in a DDS based on a lipid nanoemulsion (PEP NE) by using positron emission tomography (PET) imaging. To this aim, the PEP was conjugated with a chelating agent (DFO) and radiolabeled with zirconium-89 (89Zr). Then, [89Zr]-PEP was encapsulated in a novel nanoemulsion formulation, composed by vitamin E, sphingomyelin, and a lipid-PEG. Afterward, healthy rats were administered with either the [89Zr]-PEP or the [89Zr]-PEP-NE via IA injection and underwent PET scans at 0.5-, 24-, 48-, 72-, 168-, 240- and 336 h post-injection. To assess the biodistribution of both radiotracers, several volume-of-interest were manually drawn in different organs of the rat body and the %ID/organ was calculated. The [89Zr]-PEP was successfully encapsulated in the NE and their physicochemical properties were minimally affected by the radiolabeling buffer. Adequate stability of both [89Zr]-PEP and [89Zr]-PEP-NE was found in synovial fluid over 72 h. Quantitative data from PET images revealed a significantly higher [89Zr]-PEP-NE retention in the injected knee than with [89Zr]-PEP in all follow-up PET scans. The [89Zr]-PEP %ID/organ values in the liver and kidney were significantly higher than those from [89Zr]-PEP-NE, which might indicate a faster elimination of the [89Zr]-PEP. Therefore, the study highlights the higher retention time on the target site of the [89Zr]-PEP-NE which may improve the therapeutic effects of the peptide. Thereby, the novel nanoemulsion formulation seems to be a successful DDS for IA injection. In addition, these results represent the first study that evaluates the distribution of a PET-guided DDS after its IA administration. [Display omitted] • First study showing the distribution of a PET-guided DDS after IA injection. • Ready to inject NEs were effectively prepared using [89Zr]-PEP by one-step method. • PET data shows higher retention of the [89Zr]-PEP-NE in the injected joint. • Development of a novel nanoemulsion formulation for increasing IA retention. • Results suggest that the assessed PEP-NE has potential use in osteoarthritis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01683659
Volume :
356
Database :
Academic Search Index
Journal :
Journal of Controlled Release
Publication Type :
Academic Journal
Accession number :
162847309
Full Text :