Improvement in plan quality after Implementation of clinical goals in a large network of cancer centers.

Authors :
Liu, Hefei
Nuksani, Praveen
Rajagopalan, Malolan
Patil, Mangesh
Komanduri, Krishna
Murphy, Brent
Khuntia, Deepak
Beriwal, Sushil
Source :
Medical Dosimetry. Spring2023, Vol. 48 Issue 1, p51-54. 4p.
Publication Year :
2023

Abstract

Clinical Goals (CG) is a tool available in the Varian Eclipse planning system to objectively and visually evaluate the quality of treatment plans based upon user-defined dose-volume parameters. We defined a set of CG for Stereotactic Radiosurgery (SRS) and Intensity-Modulated Radiotherapy (IMRT) based on published data and guidelines and implemented this in a network of cancer centers in India (American Institute of Oncology). A dosimetric study was performed to compare brain SRS and breast IMRT plan quality before and after CG implementation.The CG defined for SRS plans were target V 100% ≥ 98%, dose gradient measure (GM) ≤ 0.5 cm, conformity index (CI) 1.0 to 1.2. For breast IMRT plans, CG defined target V 100% ≥ 97%, V 95% ≥ 95%, V 107% ≤ 2%, V 105% ≤ 10%, and D max ≤ 2.4 Gy. Dose limits to organs-at-risk (OAR) were summarize in supplemental materials. Twenty brain SRS and 10 breast IMRT treatment plans that were previously delivered on patients were selected and re-planned using CG. The pre and postoptimized plan parameters were compared using student t-tests.For brain SRS plans, the V 100 , GM, and CI for the pre- and post-Clinical-Goals plans were 93.22% ± 7.2% vs 97.96% ± 0.29% (p = 0.009), 0.63 ± 0.16 vs 0.42 ± 0.05 (p < 0.001) and 1.07 ± 0.18 vs 1.06 ± 0.06 (p = 0.79), respectively. There were no differences in max dose to OARs. In breast IMRT plans, the target V 107% for pre and postimplemented plans were 16.50% ± 10.98% vs 0.32% ± 0.32%, respectively (p = 0.001). The average target V 105% were 44.00% ± 15.72% and 8.69% ± 4.53%, respectively (p < 0.001). No differences were found in the average target V 100% (p = 0.128) and V 95% (p = 0.205). The average target D max were 112.28% ± 1.59% and 109.14% ± 0.73%, respectively (p < 0.001). There were only minor differences in doses to OARs.The implementation of CG in Varian Eclipse significantly improved SRS and IMRT plan quality with enhanced coverage, dose GM, and CI without increased dose to OARs. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09583947
Volume :
48
Issue :
1
Database :
Academic Search Index
Journal :
Medical Dosimetry
Publication Type :
Academic Journal
Accession number :
162288668
Full Text :
https://doi.org/10.1016/j.meddos.2022.10.003