Back to Search Start Over

Engineering a modular 44Ti/44Sc generator: eluate evaluation in preclinical models and estimation of human radiation dosimetry.

Authors :
Benabdallah, Nadia
Zhang, Hanwen
Unnerstall, Ryan
Fears, Amanda
Summer, Lucy
Fassbender, Michael
Rodgers, Buck E.
Abou, Diane
Radchenko, Valery
Thorek, Daniel L. J.
Source :
EJNMMI Research. 2/28/2023, Vol. 13 Issue 1, p1-10. 10p.
Publication Year :
2023

Abstract

Background: 44Sc/47Sc is an attractive theranostic pair for targeted in vivo positron emission tomographic (PET) imaging and beta-particle treatment of cancer. The 44Ti/44Sc generator allows daily onsite production of this diagnostic isotope, which may provide an attractive alternative for PET facilities that lack in-house irradiation capabilities. Early animal and patient studies have demonstrated the utility of 44Sc. In our current study, we built and evaluated a novel clinical-scale 44Ti/44Sc generator, explored the pharmacokinetic profiles of 44ScCl3, [44Sc]-citrate and [44Sc]-NODAGA (1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid) in naïve mice, and estimated the radiation burden of 44ScCl3 in humans. Methods: 44Ti/44Sc (101.2 MBq) in 6 M HCl solution was utilized to assemble a modular ZR resin containing generator. After assembly, 44Sc was eluted with 0.05 M HCl for further PET imaging and biodistribution studies in female Swiss Webster mice. Based on the biodistribution data, absorbed doses of 44/47ScCl3 in human adults were calculated for 18 organs and tissues using the IDAC-Dose software. Results: 44Ti in 6 M HCl was loaded onto the organic resin generator with a yield of 99.97%. After loading and initial stabilization, 44ScCl3 was eluted with 0.05 M HCl in typical yields of 82.9 ± 5.3% (N = 16), which was normalized to the estimated generator capacity. Estimated generator capacity was computed based on elution time interval and the total amount of 44Ti loaded on the generator. Run in forward and reverse directions, the 44Sc/44Ti ratio from a primary column was significantly improved from 1038 ± 440 to 3557 ± 680 (Bq/Bq) when a secondary, replaceable, ZR resin cartridge was employed at the flow outlet. In vivo imaging and ex vivo distribution studies of the reversible modular generator for 44ScCl3, [44Sc]-citrate and [44Sc]-NODAGA show that free 44Sc remained in the circulation significantly longer than the chelated 44Sc. The dose estimation of 44ScCl3 reveals that the radiation burden is 0.146 mSv/MBq for a 70 kg adult male and 0.179 mSv/MBq for a 57 kg adult female. Liver, spleen and heart wall will receive the highest absorbed dose: 0.524, 0.502, and 0.303 mGy/MBq, respectively, for the adult male. Conclusions: A clinical-scale 44Ti/44Sc generator system with a modular design was developed to supply 44ScCl3 in 0.05 M HCl, which is suitable for further radiolabeling and in vivo use. Our data demonstrated that free 44ScCl3 remained in the circulation for extended periods, which resulted in approximately 10 times greater radiation burden than stably chelated 44Sc. Stable 44Sc/47Sc-complexation will be more favorable for in vivo use and for clinical utility. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2191219X
Volume :
13
Issue :
1
Database :
Academic Search Index
Journal :
EJNMMI Research
Publication Type :
Academic Journal
Accession number :
162138350