Back to Search Start Over

Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging.

Authors :
Klingebiel, M.
Weiland, E.
Boschheidgen, M.
Ullrich, T.
Arsov, C.
Radtke, J.P.
Benkert, T.
Nickel, M.
Strecker, R.
Wittsack, H.J.
Albers, P.
Antoch, G.
Schimmöller, L.
Source :
Magnetic Resonance Imaging (0730725X). May2023, Vol. 98, p55-61. 7p.
Publication Year :
2023

Abstract

Diffusion weighted imaging (DWI) is the most important sequence for detection and grading prostate cancer (PCa), but it is considerably prone to artifacts. New approaches like zoomed single-shot imaging (z-EPI) with advanced image processing or multi-shot readout segmentation (rs-EPI) try to improve DWI quality. This study evaluates objective and subjective image quality (IQ) of rs-EPI and z-EPI with and without advanced processing. Fifty-six consecutive patients (67 ± 8 years; median PSA 8.3 ng/ml) with mp-MRI performed at 3 Tesla between February and October 2019 and subsequently verified PCa by targeted plus systematic MRI/US-fusion biopsy were included in this retrospective single center cohort study. Rs - EPI and z-EPI were prospectively acquired in every patient. Signal intensities (SI) of PCa and benign tissue in ADC, b1000, and calculated high b-value images were analyzed. Endpoints were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), PCa contrast intensity (CI), and subjective IQ on a 5-point scale evaluated by three blinded readers. Wilcoxon signed rank test, Friedman test and Cohen's kappa coefficient was calculated. SNR, CNR, and PCa CI of z-EPI with and without advanced processing was superior to rs-EPI (p < 0.01), whereas no significant differences were observed between z-EPI with and without advanced processing. Subjective IQ was significantly higher for z-EPI with advanced processing compared rs-EPI for ADC, b1000, and calculated high b-values (p < 0.01). Compared to z-EPI without advanced processing, z-EPI with advanced processing was superior for ADC and calculated high b-values (p < 0.01), but no significant differences were shown for b1000 images. Z -EPI with and without advanced processing was superior to rs-EPI regarding objective imaging parameters and z-EPI with advanced processing was superior to rs-EPI regarding subjective imaging parameters for the detection of PCa. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0730725X
Volume :
98
Database :
Academic Search Index
Journal :
Magnetic Resonance Imaging (0730725X)
Publication Type :
Academic Journal
Accession number :
161719888
Full Text :
https://doi.org/10.1016/j.mri.2023.01.010