Back to Search
Start Over
Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging.
- Source :
-
Magnetic Resonance Imaging (0730725X) . May2023, Vol. 98, p55-61. 7p. - Publication Year :
- 2023
-
Abstract
- Diffusion weighted imaging (DWI) is the most important sequence for detection and grading prostate cancer (PCa), but it is considerably prone to artifacts. New approaches like zoomed single-shot imaging (z-EPI) with advanced image processing or multi-shot readout segmentation (rs-EPI) try to improve DWI quality. This study evaluates objective and subjective image quality (IQ) of rs-EPI and z-EPI with and without advanced processing. Fifty-six consecutive patients (67 ± 8 years; median PSA 8.3 ng/ml) with mp-MRI performed at 3 Tesla between February and October 2019 and subsequently verified PCa by targeted plus systematic MRI/US-fusion biopsy were included in this retrospective single center cohort study. Rs - EPI and z-EPI were prospectively acquired in every patient. Signal intensities (SI) of PCa and benign tissue in ADC, b1000, and calculated high b-value images were analyzed. Endpoints were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), PCa contrast intensity (CI), and subjective IQ on a 5-point scale evaluated by three blinded readers. Wilcoxon signed rank test, Friedman test and Cohen's kappa coefficient was calculated. SNR, CNR, and PCa CI of z-EPI with and without advanced processing was superior to rs-EPI (p < 0.01), whereas no significant differences were observed between z-EPI with and without advanced processing. Subjective IQ was significantly higher for z-EPI with advanced processing compared rs-EPI for ADC, b1000, and calculated high b-values (p < 0.01). Compared to z-EPI without advanced processing, z-EPI with advanced processing was superior for ADC and calculated high b-values (p < 0.01), but no significant differences were shown for b1000 images. Z -EPI with and without advanced processing was superior to rs-EPI regarding objective imaging parameters and z-EPI with advanced processing was superior to rs-EPI regarding subjective imaging parameters for the detection of PCa. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0730725X
- Volume :
- 98
- Database :
- Academic Search Index
- Journal :
- Magnetic Resonance Imaging (0730725X)
- Publication Type :
- Academic Journal
- Accession number :
- 161719888
- Full Text :
- https://doi.org/10.1016/j.mri.2023.01.010