Optimization of Two-Phase Ejector Mixing Chamber Length under Varied Liquid Volume Fraction.

Authors :
Yan, Jia
Shu, Yuetong
Jiang, Jing
Wen, Huaqin
Source :
Entropy. Jan2023, Vol. 25 Issue 1, p7. 21p.
Publication Year :
2023

Abstract

The ejector performance varies with the mixing chamber length which is largely dependent on the fluid liquid volume fraction at the inlet. In this study, numerical simulations are conducted to optimize two mixing chamber lengths of a two-phase ejector under varied liquid volume fractions of 0–0.1 in two inlet fluids. The main findings are as follows: (1) The two optimal lengths of constant-pressure and constant-area mixing chambers are identified within 23–44 mm and 15–18 mm, respectively, when the primary inlet fluid is in two-phase; (2) the two optimal lengths are 2–5 mm and 9–15 mm, respectively, when the secondary inlet fluid is in two-phase; (3) when both inlets are in two-phase, the two optimal lengths are ranged in 5–23 mm and 6–18 mm; (4) little liquid within inlet fluid has a significant influence on ejector performances; and (5) optimal constant-pressure mixing chamber length and the sum of the two optimal lengths increase with the primary flow inlet liquid volume fraction but decrease with that of the secondary flow inlet. [ABSTRACT FROM AUTHOR]