Back to Search Start Over

Particulate air pollution in the Copenhagen metro part 1: Mass concentrations and ventilation.

Authors :
Kappelt, Niklas
Russell, Hugo S.
Fessa, Dafni
Ryswyk, Keith Van
Hertel, Ole
Johnson, Matthew S.
Source :
Environment International. Jan2023, Vol. 171, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

[Display omitted] • Sources and dynamics of harmful particles in metro systems are not well characterised. • Fine particulate matter and CO2 were measured in the entire Copenhagen Metro. • High particle concentrations were found despite the system's modernity. • A closed tunnel design and carriage ventilation with tunnel air are the likely causes of the problem. • Sliding doors alone are insufficient for keeping the air clean in carriages and at stations. The Copenhagen Metro comprises four lines, the M1, M2, M3 and M4, with 25 subterranean stations and an additional 14 stations above ground, serving ca. 80 million passengers annually. In this study we measure fine particulate matter (PM 2.5) and carbon dioxide (CO 2) concentrations in stations and in trains across the entire system. In partially underground lines, high PM 2.5 concentrations with an average of 109 μg m−3 are found in below-ground stations. The observed correlation between PM 2.5 concentration and distance between a station and a tunnel exit is attributed to ventilation via the piston effect. The piston effect via tunnel draught relief shafts was therefore found to be relatively limited. Filter samples of particulate matter are analysed using particle-induced X-ray emission and show an iron content of 88.6 % by mass which is quite different from above-ground particulate matter and consistent with particle production by train wheels, rails and brakes. The average concentration measured at the stations of a recently opened (2019) fully underground M3 closed loop line is 168 μg m−3, further demonstrating that while piston effect-driven ventilation is effective in close proximity to tunnel openings, it is relatively limited via tunnel draught relief shafts. Measurements onboard trains show even higher PM 2.5 concentrations and the patterns in CO 2 concentrations suggest carriage ventilation by tunnel air. Ventilation via doors during platform stops caused a drop in observed PM (and CO 2) at stations, but the system is surprisingly polluted despite its recent construction. CO 2 mixing ratios ranged from ambient to around 600 ppm. Measures should be taken to control PM levels using a combination of source control and increased clean air supply of the Copenhagen and other similar metro systems. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01604120
Volume :
171
Database :
Academic Search Index
Journal :
Environment International
Publication Type :
Academic Journal
Accession number :
161344931
Full Text :
https://doi.org/10.1016/j.envint.2022.107621