Back to Search Start Over

Micellar Electrokinetic Chromatography of X-Ray Film Developing Baths.

Authors :
Pranaityte, Birutė
Daunoravičius, Žydrūnas
Padarauskas, Audrius
Source :
Microchimica Acta. Feb2005, Vol. 149 Issue 1/2, p49-54. 6p.
Publication Year :
2005

Abstract

A simple and fast micellar electrokinetic chromatographic (MEKC) method for the determination of five main compounds (hydroquinone, metol, phenidone, 2-hydroxy-5-methylaminobenzenesulphonate and 2,5-dihydroxybenzenesulphonate) in X-ray film developing solutions was developed. The optimal conditions for the separation were established by varying the concentration of sodium dodecyl sulfate (SDS), the electrolyte pH and the temperature. Successful results were obtained with a 25?mmol?L-1 Tris-phosphate buffer at pH 9.0 in the presence of 50?mmol?L-1 SDS using direct UV detection at 214?nm. Under these conditions, baseline separation of the five compounds was achieved in less than 8?min. The method was validated in terms of precision, linearity, accuracy, and successfully applied to the analysis of X-ray film developing baths. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00263672
Volume :
149
Issue :
1/2
Database :
Academic Search Index
Journal :
Microchimica Acta
Publication Type :
Academic Journal
Accession number :
16125805
Full Text :
https://doi.org/10.1007/s00604-004-0307-2