Back to Search Start Over

CALIBRATION OF REFERENCE TORQUE TRANSDUCER IN ONE DIRECTION AND USE OF ITS CUBIC COEFFICIENTS IN BOTH DIRECTIONS WITH IMPROVED INTERPOLATION ERROR.

Authors :
Khaled, K. M.
Osman, Seif M.
Source :
Metrology & Measurement Systems. 2022, Vol. 29 Issue 3, p539-551. 13p.
Publication Year :
2022

Abstract

The current research work presents an investigation into use of the fitting coefficients resulting from the cubic curve fitting of the torque transducer calibration results in one direction to calculate the actual torque in the other torque direction with two methods: one is direct substitution with the nominal torque which gives a propagated linear relative interpolation error and the other is changing the sign of the second coefficient in the cubic function when using in the other torque direction. This proposed modification improves the absolute relative interpolation error by 5 to 16 times in the clockwise and counterclockwise directions based on the torque transducer's classification. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20809050
Volume :
29
Issue :
3
Database :
Academic Search Index
Journal :
Metrology & Measurement Systems
Publication Type :
Academic Journal
Accession number :
160797102
Full Text :
https://doi.org/10.24425/mms.2022.142272