Back to Search Start Over

Equivalent keratometer reading para cálculo biométrico em córneas assimétricas: série de casos.

Authors :
Tavares Ferreira, Diego de Queiroz
Carlos Meireles, Antônio
Gustavo Fernandes, Arthur
Brant Fernandes, Rodrigo Antônio
Source :
Revista Brasileira de Oftalmologia. 2022, Vol. 81, p1-6. 6p.
Publication Year :
2022

Abstract

The accuracy of the intraocular lens calculation is not perfect, and postoperative refractive errors are common, especially in patients who have undergone previous refractive surgery or in presence of asymmetric corneas. Corneal power after refractive surgery can be more accurately measured using the total optical power map in the 4-mm central zone, by means of Orbscan II or equivalent keratometric reading map available on pentacam, with central measurements of 1.0, 2.0, 3.0 and 4.5 mm. The purpose of this case series is to demonstrate four approaches performed in special corneal conditions, using pentacam equivalent keratometric reading to measure corneal power and biometrics, and comparing with possible results obtained with other strategies. The four eyes were submitted to previous refractive procedures, and the intraocular lens chosen from the use of the corneal power calculated by equivalent keratometric reading showed excellent postoperative results. [ABSTRACT FROM AUTHOR]

Details

Language :
Portuguese
ISSN :
00347280
Volume :
81
Database :
Academic Search Index
Journal :
Revista Brasileira de Oftalmologia
Publication Type :
Academic Journal
Accession number :
160748980
Full Text :
https://doi.org/10.37039/1982.8551.20220004