Back to Search Start Over

Retrospective longitudinal assessment of ultrasound gout lesions using the OMERACT semi-quantitative scoring system.

Authors :
Christiansen, Sara Nysom
Østergaard, Mikkel
Slot, Ole
Fana, Viktoria
Terslev, Lene
Source :
Rheumatology. Dec2022, Vol. 61 Issue 12, p4711-4721. 11p.
Publication Year :
2022

Abstract

Objectives The objectives of this study were (i) to evaluate the responsiveness of gout-specific US lesions representing urate deposition in patients receiving treat-to-target urate-lowering therapy using a binary and the OMERACT-defined semi-quantitative scoring systems; (ii) to determine the most responsive US measure for urate deposition and the optimal joint/tendon set for monitoring this. Methods US (28 joints, 14 tendons) was performed in microscopically verified gout patients initiating/increasing urate-lowering therapy and repeated after 6 and 12 months. Static images/videos of pathologies were stored and scored binarily and semi-quantitatively for tophus, double contour sign (DC) and aggregates. Lesion scores were calculated at patient level, as were combined crystal sum scores. Responsiveness of lesions—scored binarily and semi-quantitatively—was calculated at both patient and joint/tendon levels. Results Sixty-three patients underwent longitudinal evaluation. The static images/videos assessed retrospectively showed statistically significant decreases in tophus and DC, when scored binarily and semi-quantitatively, whereas aggregates were almost unchanged during follow-up. The responsiveness of the semi-quantitative tophus and DC sum scores were markedly higher than when using binary scoring. The most responsive measure for urate deposition was a combined semi-quantitative tophus-DC-sum score. A feasible joint/tendon set for monitoring included knee and first–second MTP joints and peroneus and distal patella tendons (all bilateral), representing the most prevalent and responsive sites. Conclusion The OMERACT consensus-based semi-quantitative US gout scoring system showed longitudinal validity with both tophus and DC being highly responsive to treatment when assessed in static images/videos. A responsive US measure for urate deposition and a feasible joint/tendon set for monitoring were proposed and may prove valuable in future longitudinal studies. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14620324
Volume :
61
Issue :
12
Database :
Academic Search Index
Journal :
Rheumatology
Publication Type :
Academic Journal
Accession number :
160656100
Full Text :
https://doi.org/10.1093/rheumatology/keac179