Back to Search Start Over

Real-time analysis of the fine particles in volcanic plumes: A pilot study of Laser Induced Breakdown Spectroscopy with Calibration-Free approach (CF-LIBS).

Authors :
De Giacomo, A.
Dell'Aglio, M.
Salajková, Z.
Vaníčková, E.
Mele, D.
Dellino, P.
Source :
Journal of Volcanology & Geothermal Research. Dec2022, Vol. 432, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

Volcanic plumes are rich in fine juvenile ash, representing magma fragments expelled from the crater during explosive eruptions. The composition of fine ash is of primary importance for volcano monitoring and hazard assessment, but not much effort has been put until now to build portable instrumentation allowing real-time measurements. In this paper, a laboratory experiment is carried out to build and test an apparatus based on Calibration-Free Laser Induced Breakdown Spectroscopy (CF-LIBS). This methodology is extremely promising because it does not require any standard calibration strategies and the elemental composition is directly obtained by the laser-induced breakdown optical emission. In the experiment, volcanic ash samples are suspended in the air by a laser-induced shockwave in a dedicated chamber, as to mimic the conditions of a volcanic plume, and contemporaneously the laser-induced plasma (LIP) spectrum is analyzed. After spectrum acquisition, the quantitative analysis is performed using the so-called Calibration-Free (CF) analytical method, which is based on the assumption of plasma local thermodynamic equilibrium (LTE). Results show that by such methodology it is possible to measure ash composition in real-time, during its dispersion, with good precision. Based on the result of this experiment, the construction of a portable instrument to be used in the field for the monitoring of active volcanoes could be possible in the future. [Display omitted] • We present a new approach for the measurement of flying volcanic ashes based on LIBS. • The method proposed does not require calibration standards and is flexible for real application in-situ. • Volcan ash samples: deposits of the Agnano Monte-Spina Plinian eruption of Campi Flegrei and the Pompeii eruption of Vesuvius • General discussion for in-situ application of CF-LIBS on flying ash is reported for the first time. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03770273
Volume :
432
Database :
Academic Search Index
Journal :
Journal of Volcanology & Geothermal Research
Publication Type :
Academic Journal
Accession number :
160399810
Full Text :
https://doi.org/10.1016/j.jvolgeores.2022.107675