Evaluation of different analytical approaches using total reflection X-ray fluorescence systems for multielemental analysis of human tissues with different adipose content.

Authors :
Carvalho, Patrícia M.
Marguí, Eva
Kubala-Kukuś, Aldona
Banaś, Dariusz
Machado, Jorge
Casal, Diogo
Pais, Diogo
Santos, José Paulo
Pessanha, Sofia
Source :
Spectrochimica Acta Part B. Dec2022, Vol. 198, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

Elemental content plays an important role in biological processes, and so, the multielemental analysis of human tissue samples is required in biomedical research. Still, the small amount of available biological samples and the adipose content of the samples can be major setbacks for the accurate determination of elemental content. In this study, we explored the potential of several analytical approaches combined with total reflection X-ray fluorescence spectrometry (TXRF) for multielemental analysis of human tissues with different adipose content (colon, heart, liver, lung, muscle, intestine, skin, stomach, uterus, bladder and aorta). The capabilities and limitations of different sample treatment procedures (suspension and acidic digestion) and two TXRF systems with different anode configurations (Mo and W X-ray tubes) have been evaluated for such purpose. Results showed that for tissues with a higher fat content (e.g., skin, and intestine) the best strategy was the acidic digestion of the sample before TXRF analysis. However, for other tissues, acceptable results were obtained by suspending 20 mg of powdered material in 1 mL of 2 M nitric acid. A further enhancement of the limits of detection and accuracy of the results was achieved if using Mo-TXRF systems, especially for the determination of low Z elements (e.g., K, and Ca) and of elements present at low concentrations (e.g., Cu) in the human tissues. Finally, results by TXRF analysis were compared with those obtained with μ-EDXRF and ICP-OES, and a good agreement was obtained. [Display omitted] • Good quantitative compromise between techniques for medium-Z elements. • Gauging adipose content through EDXRF for decision-making in TXRF sample preparation. • Tissues with high adipose content require sample digestion procedures. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
05848547
Volume :
198
Database :
Academic Search Index
Journal :
Spectrochimica Acta Part B
Publication Type :
Academic Journal
Accession number :
160397766
Full Text :
https://doi.org/10.1016/j.sab.2022.106548