Theoretical and Experimental Study on the Thermal Insulation Performance of the Roof with Water-Retained Bricks.
- Source :
-
Entropy . Nov2022, Vol. 24 Issue 11, p1528. 22p. - Publication Year :
- 2022
-
Abstract
- In this paper, the thermal insulation performance of the roof with water-retained bricks was first analyzed theoretically with respect to the thermal inertia, attenuation and delay time of the roof with water-retained bricks. Then, the experimental rig was established to carry out the experimental research on the thermal insulation performance of the roof with and without water-retained bricks on the sunny, overcast and rainy days in the summer and on the sunny day in the winter. The results showed that: (1) the surface heat storage coefficient is affected by the evaporating heat transfer of the water layer; (2) the thermal inertness, attenuation and delay time of the roof with water-retained bricks are 2.575, 21 and 6.94 h, respectively, when the water depth is 2 cm; (3) on the sunny, overcast and rainy days in the summer, laying water-retained bricks can enhance the heat insulation performance of the roof, and can improve the thermal comfort of the loft; and (4) on the sunny day in the winter, after laying water-retained bricks, the average temperature of the loft in 24 h increases by 2.3 °C, and the temperature fluctuation of the loft decreases by 56.0%. Therefore, the thermal insulation effect is significantly improved after laying water-retained bricks on the roof from the results of both the theoretical and experimental study. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10994300
- Volume :
- 24
- Issue :
- 11
- Database :
- Academic Search Index
- Journal :
- Entropy
- Publication Type :
- Academic Journal
- Accession number :
- 160144969
- Full Text :
- https://doi.org/10.3390/e24111528