Intra- and Inter-rater Reliability of a Magnetic Resonance Imaging-Based Volumetric Analysis of the Abductor Hallucis Muscle.

Authors :
Moulodi, Nasrin
Jalali, Maryam
Sarrafzadeh, Javad
Azadinia, Fatemeh
Shakourirad, Ali
Source :
Iranian Journal of Radiology. Jul2022, Vol. 19 Issue 3, p1-8. 8p.
Publication Year :
2022

Abstract

Background: The muscle volume considerably changes with aging, pathologies, mechanical loading and exercise, and immobilization. It is recognized as an important parameter that can be measured by various methods to evaluate the effectiveness of interventions focusing on muscle strengthening and function. However, before the application of any measurement method, their reliability needs to be investigated and established. Objectives: This study aimed to evaluate the inter- and intra-rater reliability of the manual measurement method of the abductor hallucis muscle volume in feet with hallux valgus deformities using magnetic resonance imaging (MRI). Patients and Methods: The MRI images of the feet of 15 samples with a hallux valgus deformity were selected in this study. The cross-sectional areas of the abductor hallucis muscle were measured in the cuts along the entire length of the foot and multiplied by slice thickness. Two trained raters performed the measurements. The second rater repeated the measurements after five days to eliminate the memory effect. The intra-rater reliability and inter-rater reliability were assessed based on the intraclass correlation coefficient [ICC (2, 1)] to evaluate the extent of agreement between the raters at a 95% confidence interval. Results: The between- and within-rater ICCs were 0.92 (0.79 - 0.97) and 0.99 (0.97 - 0.99), respectively. The standard error of measurements was also small in both inter-rater (6.2%) and intra-rater (2.1%) reliability analyses. Conclusion: The manually outlined slice-by-slice volume measurement of the abductor hallucis muscle based on MRI images showed excellent inter- and intra-rater reliability. The excellent intra-rater reliability, besides the lower standard error percentage of measurements, indicates the superiority of measurements by a single person. However, further studies with a larger sample size are recommended. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17351065
Volume :
19
Issue :
3
Database :
Academic Search Index
Journal :
Iranian Journal of Radiology
Publication Type :
Academic Journal
Accession number :
160016210
Full Text :
https://doi.org/10.5812/iranjradiol-128725