Back to Search Start Over

Abridged validation of charm II screening tests for the detection of veterinary drug residues in fish farmed in Cameroon.

Authors :
Tsafack Takadong, Julie Judith
Gondam Kamini, Mélanie
Yangoua Mafo, Huguette
Medjo Koupestchop, Evrard
Ntsama Bouelet, Sandrine Isabelle
Tatfo Keutchatang, Fabrice De Paul
Sasanya, James
Medoua Nama, Gabriel
Source :
Food Additives & Contaminants. Part A: Chemistry, Analysis, Control, Exposure & Risk Assessment. Oct2022, Vol. 39 Issue 10, p1691-1704. 14p. 1 Diagram, 11 Charts, 1 Graph.
Publication Year :
2022

Abstract

The intensification of aquaculture in Cameroon requires efficient screening methods to control veterinary drug residues in fish. This is why the charm II radio receptor technique for the detection of antimicrobial residues in aquaculture fish initiated in Belgium was transferred to Cameroon according to Commission Decision 2002/657/EC. The validation parameters included the following tests: repeatability, reproducibility and robustness in addition to the mandatory characteristics, detection capability and specificity. Selected veterinary drug-free fish samples of tilapia (Oreochromis niloticus), catfish (Clarias gariepinus), carp (Cyprinus Carpio) and kanga (Heterotis niloticus) were spiked at different target concentrations with different antimicrobials (β-lactams, tetracycline, sulfonamides, macrolides and chloramphenicol). The detection capabilities (CCβ) were at MRPL (0.3 µg/kg for chloramphenicol), or below the regulatory limits in a range of 0.25–0.5 MRL with 0% false-negative results. β-lactams (penicillin G), tetracyclines (tetracycline, chloretetracycline and oxytetracycline) and macrolides (erythromycine A) were detected at half MRL (25, 50 and 100 µg/kg respectively), while sulfonamides (sulfamethazine) was detected at 25 µg/kg (0.25 MRL). The detection capabilities (CCβ) obtained were satisfactory as the cut-off factors (Fm) were less than the mean values of blank fish readings (B) (Fm < B). Furthermore, the method was applicable since the cut-off factor was less than the positivity threshold (Fm < T). The variability of the data under repeatability and reproducibility conditions was acceptable, with a relative standard deviation less than 15%. Results were unaffected by delaying the reading time from 0 h to 24 h after the addition of scintillation fluid, with a precision below 16%. Likewise, non-target drugs were not detected even at high concentrations (100 MRL) in a cross-reactivity study. From the overall results, the performance characteristics (detection capabilities, precision, robustness and specificity) were suitable and comparable to the initial validation results, indicating that the transfer to Cameroon laboratory was valid, the method was reliable and could be used in aquaculture fish quality monitoring programs in Cameroon. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19440049
Volume :
39
Issue :
10
Database :
Academic Search Index
Journal :
Food Additives & Contaminants. Part A: Chemistry, Analysis, Control, Exposure & Risk Assessment
Publication Type :
Academic Journal
Accession number :
159583489
Full Text :
https://doi.org/10.1080/19440049.2022.2107710