Back to Search Start Over

Comparative evaluation of bacterial and fungal removal of indoor and industrial polluted air using suspended and packed bed bioreactors.

Authors :
Cantera, Sara
López, Martino
Muñoz, Raúl
Lebrero, Raquel
Source :
Chemosphere. Dec2022:Part 2, Vol. 308, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

The abatement of indoor volatile organic compounds (VOCs) represents a major challenge due to their environmental risk, wide nature and concentration variability. Biotechnologies represent a cost-effective, robust and sustainable platform for the treatment of hazardous VOCs at low and fluctuating concentrations. However, they have been scarcely implemented for indoor air purification. Thus, little is known about the influence of the reactor configuration or the VOC nature and concentration variability on the removal, resilience and the microbial population of bioreactor configurations susceptible to be implemented, both in indoors and industrial environments. The present study aims at comparing the removal performance of four VOCs with different hydrophobicity and molecular structure -acetone, n -hexane, α-pinene and toluene-at two inlet concentrations (5 and 400 mg m−3), which mimics the concentrations of contaminated indoor and industrial air. To this aim a stirred tank, flat biofilm and latex-based biocoated flat bioreactor were comparatively evaluated. The results demonstrated the superior performance of the stirred tank reactor for the removal of hydrophilic VOCs at high inlet concentrations, which achieved removals >99% for acetone and toluene. At low concentrations, the removal efficiencies of acetone, toluene and α-pinene were >97% regardless of the bioreactor configuration tested. The most hydrophobic gas, n -hexane, was more efficiently removed in the flat biofilm reactor without latex. The microbial community analyses showed that the presence of VOCs as the only carbon and energy source didn't promote the growth of dominant bacterial members and the populations independently evolved in each reactor configuration and operation mode. The fungal population was more diverse in the biofilm-based bioreactors, although, it was mainly dominated by uncultured fungi from the phylum Cryptomycota. [Display omitted] • Comparison of different reactor configurations for the removal of indoor air VOCs. • The stirred tank reactor showed the best VOC removals at high inlet concentrations. • VOC removals>97% achieved at low inlet concentration in all reactor configurations. • n -hexane was more efficiently removed in a flat biofilm reactor without latex. • The specific operation mode affected the bacterial and fungal population. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00456535
Volume :
308
Database :
Academic Search Index
Journal :
Chemosphere
Publication Type :
Academic Journal
Accession number :
159570835
Full Text :
https://doi.org/10.1016/j.chemosphere.2022.136412