Back to Search Start Over

Experimental study on the effect of the split-type air-conditioner on the transmission of smoking pollutants in a room.

Authors :
Xie, Ruoyi
Xu, Yiyang
Chen, Guangming
Zhang, Shaozhi
Source :
Journal of the Air & Waste Management Association (Taylor & Francis Ltd). Oct2022, Vol. 72 Issue 10, p1113-1120. 8p.
Publication Year :
2022

Abstract

Environmental tobacco smoke (ETS) has become one of the most important sources of indoor air pollution. The study aimed to obtain the variation characteristics of typical air pollutant concentrations when people smoke in a closed room and explore the effect of the air-conditioner. A closed and air-conditioned room of 21 m2 was taken as the research object. Fine particulate matter (PM2.5) and total volatile organic compound (TVOC) were measured while 10 cigarettes were burnt in smoldering or smoking mode, with the air-conditioner on or off. The contents of nicotine in condensate samples were obtained by liquid chromatography. The impact of ETS on indoor air quality lasted for hours, causing typical pollutant concentrations to far exceed the Chinese standard. The PM2.5 produced by smoking was 11 times higher than by smoldering, but the TVOC produced by smoldering was more than by smoking. After one hour of the cigarette burning off, the PM2.5 concentration would be decreased by 96.1% with the air-conditioner on, in contrast to 67.9% with the air-conditioner off. Nicotine was detected in all samples of condensate from the air-conditioner. It is concluded that smoking cigarettes cannot be replaced by smoldering to evaluate the pollution of ETS. The air-conditioner has a positive effect on reducing the concentration of air pollutants produced by cigarette burning. More than 10% of the indoor nicotine may be taken away by condensate discharge, and its possible pollution should be paid attention to. Implications: This study provides new evidence of the effect of the split-type air-conditioner on ETS. The TVOC concentrations, which were less considered previously, were measured. PM2.5 concentration in human breathing zone can be reduced more quickly with the air-conditioner on. This study shows that there is a big difference in the concentrations of typical pollutants between smoking and smoldering. And it could be a guide for the formulation of relevant research methods. This study also demonstrates that the air conditioning condensate from the smoking room may contain nicotine. Attention should be paid to the recovery and utilization of such condensate. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10962247
Volume :
72
Issue :
10
Database :
Academic Search Index
Journal :
Journal of the Air & Waste Management Association (Taylor & Francis Ltd)
Publication Type :
Academic Journal
Accession number :
159447904
Full Text :