Back to Search Start Over

Multi-parametric whole-body MRI evaluation discerns vital from non-vital multiple myeloma lesions as validated by 18F-FDG and 11C-methionine PET/CT.

Authors :
Heidemeier, Anke
Schloetelburg, Wiebke
Thurner, Annette
Metz, Corona
Heidemeier, Heike
Rasche, Leo
Martin Kortuem, K.
Boeckle, David
Weiland, Elisabeth
Benkert, Thomas
Nickel, Dominik
Werner, Rudolf
Buck, Andreas Konrad
Bley, Thorsten Alexander
Source :
European Journal of Radiology. Oct2022, Vol. 155, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

<bold>Purpose: </bold>We tested a novel multi-parametric (mp) whole body (WB)-MRI evaluation algorithm for medullary lesions in comparison to positron emission tomography (PET) radiotracers 18F-fluorodeoxyglucose (18F-FDG) and 11C-methionine (11C-MET).<bold>Methods and Materials: </bold>This retrospective single-center study included 44 MM patients, who received both 18F-FDG-PET and WB-MRI within ten days. MRI classified focal lesions as vital when showing 1) significant diffusion-restriction, 2) a fat fraction (FF) less than 20 % and 3) homogenous hypointensity on T2-weighted images. On a lesion-by-lesion level the findings were compared to 18F-FDG PET by using a 5-point scoring system (analogous to the Deauville score [DS]). In 24/44 (55 %) patients additional comparison to 11C-MET PET was available.<bold>Results: </bold>Among two radiologists, an excellent inter-observer reliability for mpWB-MRI in a total of 84 medullary lesions was observed (ICC = 1, k = 1, p <.01). 16/17 (94.1 %) MRI-classified vital lesions had a DS of 4 or 5 on either 18F-FDG-PET or 11C-MET-PET. MRI-rated non-vital lesions correlated with PET-based DS ≤ 3. When results of mpWB-MRI were compared to 18F-FDG, a fair inter-observer agreement was recorded (ICC = 0.52, k = 0.53, p <.01), while for 11C-MET, an excellent concordance rate was achieved (ICC = 0.81, k = 0.79, p <.01).<bold>Conclusion: </bold>The proposed mpWB-MRI interpretation algorithm allowed to assess tumor activity of myeloma lesions with high inter-observer reproducibility. We observed a substantial concordance between the mpWB-MRI classification of lesions and PET assessment based on a semi-automatically calculated 5-point scoring system analogous to the Deauville scores. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0720048X
Volume :
155
Database :
Academic Search Index
Journal :
European Journal of Radiology
Publication Type :
Academic Journal
Accession number :
159215807
Full Text :
https://doi.org/10.1016/j.ejrad.2022.110493