Back to Search Start Over

Accuracy of QuantiFERON SARS-CoV-2 research use only assay and characterization of the CD4+ and CD8+ T cell-SARS-CoV-2 response: comparison with a homemade interferon-γ release assay.

Authors :
Aiello, Alessandra
Coppola, Andrea
Vanini, Valentina
Petrone, Linda
Cuzzi, Gilda
Salmi, Andrea
Altera, Anna Maria Gerarda
Tortorella, Carla
Gualano, Gina
Gasperini, Claudio
Scolieri, Palma
Beccacece, Alessia
Vita, Serena
Bruzzese, Vincenzo
Lorenzetti, Roberto
Palmieri, Fabrizio
Nicastri, Emanuele
Goletti, Delia
Source :
International Journal of Infectious Diseases. Sep2022, Vol. 122, p841-849. 9p.
Publication Year :
2022

Abstract

• The QuantiFERON SARS-CoV-2 research use only assay response is mediated by CD4+ and CD8+ T cells. • Immune response to the antigen (Ag)2 tube is more accurate than that to the Ag1 tube. • Responses to QuantiFERON SARS-CoV-2 tubes are lower compared with a homemade test. • The QuantiFERON SARS-CoV-2 difference in accuracy is likely because of the peptide composition. Objectives: In this study, we aimed to characterize the SARS-CoV-2-specific T cell response detected by the QuantiFERON SARS-CoV-2 research use only assay in terms of accuracy and T cell subsets involved compared with a homemade interferon (IFN)-γ release assay (IGRA). Methods: We evaluated T cell response by the standardized QuantiFERON SARS-CoV-2 tubes (antigen [Ag]1 and Ag2) and a homemade IGRA quantifying IFN-γ response to SARS-CoV-2 spike peptides (homemade-IGRA-SPIKE test). We evaluated the T cell subsets mediating the specific response using flow cytometry. Results: We prospectively enrolled 66 individuals: COVID-19 or post-COVID-19 subjects and NO-COVID-19-vaccinated subjects, including healthy donors and immunocompromised subjects. The standardized kit detected 62.1% (41/66) of T cell responders. Ag2 tube showed a higher IFN-γ quantitative and qualitative response. Ag1 tube response was mainly mediated by CD4+ T cells; Ag2 tube response was mediated by CD4+ and CD8+ T cells. The homemade-IGRA-SPIKE test detected a higher number of responders (52/66, 78.8%) than the QuantiFERON SARS-CoV-2 assay (P = 0.056). The response was found in both T cell subsets, although a higher magnitude and response rate was observed in the CD4+ T cell subset. Conclusion: The QuantiFERON SARS-CoV-2 response is mediated by CD4+ and CD8+ T cells. A lower number of responders is found compared with the homemade-IGRA-SPIKE test, likely because of the different peptide composition. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
12019712
Volume :
122
Database :
Academic Search Index
Journal :
International Journal of Infectious Diseases
Publication Type :
Academic Journal
Accession number :
158887493
Full Text :
https://doi.org/10.1016/j.ijid.2022.07.049