Back to Search
Start Over
Bone versus soft-tissue setup in proton therapy for patients with oesophageal cancer.
- Source :
-
Acta Oncologica . Aug2022, Vol. 61 Issue 8, p994-1003. 10p. 2 Color Photographs, 3 Graphs. - Publication Year :
- 2022
-
Abstract
- The aim of this study was to investigate the effect of patient positioning based on either bone or soft-tissue matching for PT in oesophageal cancer and its impact on plan adaptation. Two retrospective patient cohorts treated with radiotherapy were included in the study. Cohort A consisted of 26 consecutive patients with a planning 4DCT scan (CT1) and a surveillance 4DCT scan (CT2) at fraction ten. Cohort B consisted of 17 patients selected based on large anatomical changes identified during treatment resulting in a rescan (CT2). Mean dose to the iCTV (sum of the CTVs in all respiratory phases) was 50.4 Gy (RBE) in 28 fractions or 41.4 Gy (RBE) in 23 fractions. A nominal pencil beam scanning plan was created using two posterior beams and robust optimization (5 mm setup, 3.5% range). For each patient, two rigid registrations were made between average (avg) CT1 and CT2: a match on the vertebral column (bone match) and a match on the iCTV (soft-tissue match). Robustness towards setup (5 mm) and range (3.5%) errors was evaluated at CT2. Robustness towards respiration was evaluated by recalculation of the plan on all phases of the CT2 scan. Dose coverage <96% would trigger adaptation. The statistical significance (p-value <0.05) between dose coverage for the two registration methods was assessed using the Wilcoxon signed rank test. All plans fulfilled V95%iCTV>99% for the nominal plan and V95%iCTV>97% for all respiratory phases and robustness scenarios at CT1. In two (8%) and three (18%) patients, V95%iCTV<96% on CT2 for Cohort A and B, respectively when bone match was used. For soft-tissue match, V95%iCTV >96% for all patients. V95%iCTV was significantly higher (p-value = 0.0001) for soft-tissue match than bone match. Anatomical changes during the treatment course led to target dose deterioration and a need for plan adaptation when using a bone match. [ABSTRACT FROM AUTHOR]
- Subjects :
- *PUBLIC health surveillance
*STATISTICS
*DIGITAL image processing
*COMPUTER software
*BONES
*PATIENT selection
*RESEARCH methodology
*RETROSPECTIVE studies
*CANCER patients
*SOFT tissue tumors
*PROTON therapy
*RADIATION doses
*RADIOTHERAPY
*DATA analysis
*COMPUTED tomography
*ESOPHAGEAL tumors
*PATIENT positioning
*LONGITUDINAL method
*RECORDING & registration
Subjects
Details
- Language :
- English
- ISSN :
- 0284186X
- Volume :
- 61
- Issue :
- 8
- Database :
- Academic Search Index
- Journal :
- Acta Oncologica
- Publication Type :
- Academic Journal
- Accession number :
- 158571796
- Full Text :
- https://doi.org/10.1080/0284186X.2022.2091949