Back to Search Start Over

Wearable Devices and Smartphone Inertial Sensors for Static Balance Assessment: A Concurrent Validity Study in Young Adult Population.

Authors :
Rodrigues, Luciana Abrantes
Santos, Enzo Gabriel Rocha
Santos, Patrícia Seixas Alves
Igarashi, Yuzo
Oliveira, Luana Karine Resende
Pinto, Gustavo Henrique Lima
Santos Lobato, Bruno Lopes
Cabral, André Santos
Belgamo, Anderson
Costa e Silva, Anselmo Athayde
Callegari, Bianca
Souza, Givago Silva
Source :
Journal of Personalized Medicine. Jul2022, Vol. 12 Issue 7, p1019-1019. 14p.
Publication Year :
2022

Abstract

Falls represent a public health issue around the world and prevention is an important part of the politics of many countries. The standard method of evaluating balance is posturography using a force platform, which has high financial costs. Other instruments, such as portable devices and smartphones, have been evaluated as low-cost alternatives to the screening of balance control. Although smartphones and wearables have different sizes, shapes, and weights, they have been systematically validated for static balance control tasks. Different studies have applied different experimental configurations to validate the inertial measurements obtained by these devices. We aim to evaluate the concurrent validity of a smartphone and a portable device for the evaluation of static balance control in the same group of participants. Twenty-six healthy and young subjects comprised the sample. The validity for static balance control evaluation of built-in accelerometers inside portable smartphone and wearable devices was tested considering force platform recordings as a gold standard for comparisons. A linear correlation (r) between the quantitative variables obtained from the inertial sensors and the force platform was used as an indicator of the concurrent validity. Reliability of the measures was calculated using Intraclass correlation in a subsample (n = 14). Smartphones had 11 out of 12 variables with significant moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables in open eyes, closed eyes, and unipedal conditions, while wearable devices had 8 out of 12 variables with moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables under the same task conditions. Significant reliabilities were found in closed eye conditions for smartphones and wearables. The smartphone and wearable devices had concurrent validity for the static balance evaluation and the smartphone had better validity results than the wearables for the static balance evaluation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20754426
Volume :
12
Issue :
7
Database :
Academic Search Index
Journal :
Journal of Personalized Medicine
Publication Type :
Academic Journal
Accession number :
158267160
Full Text :
https://doi.org/10.3390/jpm12071019