Decreased Risk of Strokes in Children with Ventricular Assist Devices Within ACTION.

Authors :
Peng, David M.
Shezad, Muhammad F.
Lorts, Angela
Gajarski, Robert J.
VanderPluym, Christina
Murray, Jenna M.
Hawkins, Beth
Villa, Chet R.
Zafar, Farhan
Rosenthal, David N.
Source :
Pediatric Cardiology. Aug2022, Vol. 43 Issue 6, p1379-1382. 4p.
Publication Year :
2022

Abstract

We sought to characterize strokes in children with ventricular assist devices. Of 407 patients in the ACTION registry (4/1/18–5/3/2021), 45 (11%) experienced 52 strokes (45 ischemic and 7 hemorrhagic). Median time to stroke was 23.5 days and 19/52 (37%) occurred ≤ 10 days. Stroke rate was 0.09 and 0.63 strokes per patient-year for implantable continuous and paracorporeal devices, respectively. Patients with stroke were younger, more likely to have congenital heart disease and have been on extracorporeal membrane oxygenation at time of VAD. Based on these data, ACTION is now focused on decreasing strokes in these higher-risk patients with particular attention to the peri-implant period. [ABSTRACT FROM AUTHOR]