An Inter-Turn Short-Circuits Fault Detection Strategy Considering Inverter Nonlinearity and Current Measurement Errors for Sensorless Control of SPMSM.

Authors :
Xu, Yongxiang
Wang, Yangrui
Zou, Jibin
Source :
IEEE Transactions on Industrial Electronics. Nov2022, Vol. 69 Issue 11, p11709-11722. 14p.
Publication Year :
2022

Abstract

Aiming at the misdiagnosis problem of the interturn short-circuit (ITSC) fault detection method caused by the inverter nonlinearity and the current measurement errors, a d-axis residual voltage-based fault diagnostic strategy is proposed for sensorless control of the surface permanent magnet synchronous motor (SPMSM). The model of the three-phase wye-connected SPMSM with ITSC fault is established, and the expression of the d-axis residual voltage caused by the ITSC fault, the inverter nonlinearity, the current measurement errors and the motor parameter errors is derived. The proposed fault diagnostic strategy can eliminate the current relative gain coefficient error and locate the ITSC fault by using the eighth and second harmonics of the estimated d-axis residual voltage, respectively. The experimental results verify the effectiveness of the proposed fault diagnostic strategy. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02780046
Volume :
69
Issue :
11
Database :
Academic Search Index
Journal :
IEEE Transactions on Industrial Electronics
Publication Type :
Academic Journal
Accession number :
157325423
Full Text :