Back to Search Start Over

Comparison of experiences and preferences following non-invasive cardiovascular risk procedures: a cross-sectional survey in participants with and without diabetes mellitus.

Authors :
Lal, Anchal
Dave, Neha
Kazi, Samia
Mitchell, Paul
Thiagalingam, Aravinda
Source :
Journal of Diabetes & Metabolic Disorders. Jun2022, Vol. 21 Issue 1, p463-474. 12p.
Publication Year :
2022

Abstract

Aims: Endothelial dysfunction is an early risk marker of cardiovascular disease in diabetes mellitus. Timely screening is important in reducing cardiovascular disease-associated morbidity and mortality. This cross-sectional study investigates the acceptability and preferability of non-invasive cardiovascular risk procedures (EndoPAT2000 system and the ECG-gated fundoscope) in participants with diabetes mellitus compared to controls. Methods: A self-administered Likert scale-based questionnaire was completed by 106 controls and 117 participants with diabetes mellitus, identified through stratified random sampling, upon conclusion of an Australian Heart Eye sub-study conducted at Westmead Hospital, NSW, Australia from 2012 to 2014. Pearson's χ2 test, independent-samples t-test and regression analysis were performed. Results: Study participants who responded to the questionnaire had no preference for procedures (controls: 2.4 ± 1.1 vs diabetes mellitus: 2.5 ± 0.9, p = 0.38) but had an overall more negative experience with most aspects of the ECG-gated fundoscope than the EndoPAT2000 system. Of those with diabetes mellitus, participants who provided poorer self-rated health expressed discomfort with the mydriatic drops (ß 0.27, 95%CI 0.001 - 0.54, p = 0.049) and the fundoscope's green light filter (ß 0.27, 95%CI 0.07 - 0.47, p = 0.009), as well as maintaining still (ß 0.40, 95%CI 0.08 - 0.72, p = 0.02) and not blinking (ß 0.38, 95%CI 0.07 - 0.70, p = 0.02) during photo acquisition. These participants were also less willing to repeat the ECG-gated fundoscope procedure (ß 0.29, 95%CI 0.07 - 0.52, p = 0.01). Conclusions: Participants with diabetes mellitus, especially with poorer self-rated health, had a more negative experience with the ECG-gated fundoscope than the EndoPAT2000 system. Difficulties experienced under examination by the ECG-gated fundoscope appear related to the procedural design, which requires amendments improving patient comfort and compliance. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
22516581
Volume :
21
Issue :
1
Database :
Academic Search Index
Journal :
Journal of Diabetes & Metabolic Disorders
Publication Type :
Academic Journal
Accession number :
157263203
Full Text :
https://doi.org/10.1007/s40200-022-00996-3