Back to Search Start Over

Short Communication: Use of Infrared Thermometers for Cutaneous Temperature Recording: Agreement with the Rectal Temperature in Felis catus.

Authors :
Giannetto, Claudia
Acri, Giuseppe
Pennisi, Melissa
Piccione, Giuseppe
Arfuso, Francesca
Falcone, Annastella
Giudice, Elisabetta
Di Pietro, Simona
Source :
Animals (2076-2615). May2022, Vol. 12 Issue 10, p1275. 12p.
Publication Year :
2022

Abstract

Simple Summary: The recording of body temperature by rectal temperature assessments is a stressful procedure for cats. For this purpose, alternative methods for using rectal digital thermometers to monitor body temperature were investigated. Skin temperature was recorded in 20 cats, in 5 different body regions, and compared with the rectal temperature. The obtained data indicated that the cutaneous temperature recorded by the infrared thermometers was not in agreement with the data recorded by the digital thermometer in the rectum. In veterinary medicine, the gold standard for assessing body temperature is rectal temperature assessment. Considering that this procedure is stressful for many species, in particular for cats, it could be clinically important to consider an alternative approach for the monitoring of core body temperature. The aim of this study was to test if cutaneous temperature measurements by means of different infrared thermometers are in agreement with the most commonly used method for body temperature measurement in cats. The cutaneous temperature was recorded in the jugular, shoulder, rib, flank, and inner thigh, using three different non-contact infrared thermometers (IR1, IR2, and IR3) in 20 cats. The cutaneous temperature was then compared to the rectal temperature, recorded by means of a digital thermometer. The obtained data indicated that the cutaneous temperature recorded by the infrared thermometers was not in agreement with the data recorded by the digital thermometer in the rectum. In cats, the use of non-contact infrared thermometers gave no reproducible or constant data to justify their application for the recording of body temperature instead of rectal temperature recording. In addition, the infrared temperature measurement devices generated results that were not in good agreement among themselves, providing a novel result of clinical importance. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20762615
Volume :
12
Issue :
10
Database :
Academic Search Index
Journal :
Animals (2076-2615)
Publication Type :
Academic Journal
Accession number :
157130581
Full Text :
https://doi.org/10.3390/ani12101275