Back to Search Start Over

Analyzing the effect of existing bubbles in the interface liquid on the dynamic response of the strain-gauge type pressure sensor.

Authors :
Ghanbari, Mina
Rezazadeh, Ghader
Fathalilou, Mohammad
Source :
Measurement (02632241). Jun2022, Vol. 196, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

• Studying the main failure of the strain gauge type pressure sensors. • Mathematical modeling of a strain gauge pressure sensor in the presence of bubbles in the interface liquid. • Solving differential equations of the membrane and sensing plate displacement coupled with the nonlinear bubble dynamics equation. • The effect of the existence of bubbles on the dynamic response of the sensor. • Time-domain response of the sensing plate considering different types of applied dynamic pressure as step, single pulse, harmonic, etc. • Transient response of the sensor considering bubbles with different size. This paper studies one of the major failures, that may occur in macro-scale strain gauge pressure sensors as well as micro-scale ones. The leakage in the interface fluid chamber of the sensor causes the air to be trapped especially in the form of bubbles in the interface liquid near the boundaries. In this work, mathematical modeling of a strain gauge pressure sensor in the presence of the trapped micro-scale bubbles in the interface liquid is presented. The governing equations of displacement of the membrane and sensing plate coupled with the nonlinear dynamic equation of bubbles are solved simultaneously utilizing the Galerkin weighted residual method. The transient response of the sensor in the presence of bubbles is investigated considering different types of applied dynamic pressure as step, single pulse, repetitive pulse, and harmonic. Results indicate that when a higher percentage of the interface oil is filled with bubbles, the maximum overshoot in the response of the sensor reduces, while, the peak time, rise time, and also settling time in the response of the sensor increases. A delay is observed in the time-domain response of the sensor due to the reduction of speed of transferring data from the membrane to the sensing plate caused by the bubbles in the interface liquid. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02632241
Volume :
196
Database :
Academic Search Index
Journal :
Measurement (02632241)
Publication Type :
Academic Journal
Accession number :
157031049
Full Text :
https://doi.org/10.1016/j.measurement.2022.111255