Back to Search
Start Over
An Online Groundwall Insulation Monitoring Method Based on Transient Characteristics of Leakage Current for Inverter-Fed Motors.
- Source :
-
IEEE Transactions on Power Electronics . Aug2022, Vol. 37 Issue 8, p9745-9753. 9p. - Publication Year :
- 2022
-
Abstract
- With the wide application of inverter-fed motors (IFMs), it is necessary to monitor the groundwall (GW) insulation status to guarantee the reliable operation of motor drive system. This article first proposes a mathematical model of leakage current in IFM to analyze its time domain characteristics, and then an online GW insulation monitoring method is proposed based on the transient characteristics of leakage current. By using the initial oscillation amplitude, oscillation period, and attenuation time of leakage current, the phase, position, and severity of GW insulation degradation can be identified. The proposed method is validated using an IFM, and the experimental results agree well with theoretical analysis. [ABSTRACT FROM AUTHOR]
- Subjects :
- *STRAY currents
*ALTERNATING current electric motors
Subjects
Details
- Language :
- English
- ISSN :
- 08858993
- Volume :
- 37
- Issue :
- 8
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Power Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 156741881
- Full Text :
- https://doi.org/10.1109/TPEL.2022.3157571