Back to Search Start Over

Comparison of 5 Rectal Preparation Strategies for Prostate MRI and Impact on Image Quality.

Authors :
Sathiadoss, Paul
Haroon, Mohammad
Osman, Heba
Ahmad, Faraz
Papadatos, Philip
Schieda, Nicola
Source :
Canadian Association of Radiologists Journal. May2022, Vol. 73 Issue 2, p346-354. 9p.
Publication Year :
2022

Abstract

Purpose: To compare 5 different rectal preparation strategies for prostate MRI. Methods: This 5-arm quality-assurance study evaluated 56 patients per arm (280 patients) including: no preparation, clear-fluids diet (CFD) beginning at 00:00 hours on the day of MRI, Fleet®-enema, enema + CFD, enema + CFD + IV-antispasmodic agent. The study was powered to 0.80 with alpha-error of 0.05. Three blinded radiologists independently evaluated T2-Weighted (T2W) and Diffusion Weighed Imaging (DWI) for: rectal diameter (maximal AP diameter), rectal content (stool, fluid, gas), rectal motion, T2W/DWI image quality, T2W image sharpness and DWI susceptibility artifact using 5-point Likert scales. Overall comparisons were performed using analysis of variance (ANOVA) and Kruskal-Wallis, with pair-wise comparisons using paired t-tests and Wilcoxon sign-rank tests. Results: Rectal diameter and amount of gas were lower in enema compared to non-enema groups (p < 0.001), with smallest diameter and least gas in the enema + CFD + IV-antispasmodic group (p = 0.022-<0.001). T2W image quality and sharpness were highest in the enema + CFD groups (p < 0.001) with no difference comparing enema + CFD with/without IV-antispasmodic (p = 0.064, 0.084). Motion artifact was least in enema + CFD + IV-antispasmodic group compared to all other groups (p < 0.001), followed by the enema + CFD group (p = 0.008-<0.001). DWI image quality was highest (p < 0.001) and DWI susceptibility artifact lowest (p < 0.001) in the enema + CFD groups (p < 0.001) and did not differ comparing enema + CFD with/without anti-spasmodic (p = 0.058-0.202). Conclusions: Use of enema + clear-fluids diet before prostate MRI yields the highest T2W and DWI image quality with the least DWI artifact. IV-antispasmodic use reduces motion on T2W but does not improve image quality on T2W or DWI, or lessen DWI artifact compared to enema + clear-fluids diet. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08465371
Volume :
73
Issue :
2
Database :
Academic Search Index
Journal :
Canadian Association of Radiologists Journal
Publication Type :
Academic Journal
Accession number :
156465839
Full Text :
https://doi.org/10.1177/08465371211033753