Back to Search Start Over

SORCE and TSIS‐1 SIM Comparison: Absolute Irradiance Scale Reconciliation.

Authors :
Harder, Jerald
Béland, Stéphane
Penton, Steven V.
Richard, Erik
Weatherhead, Elizabeth
Araujo‐Pradere, Eduardo
Source :
Earth & Space Science. Mar2022, Vol. 9 Issue 3, p1-15. 15p.
Publication Year :
2022

Abstract

The Solar Radiation and Climate Experiment (SORCE) and Total and Spectral Irradiance Sensor (TSIS‐1) conducted an intercomparison for the two Spectral Irradiance Monitors (SIM) spanning 704 days from 23 March 2018 to 25 February 2020 and permitted 554 time‐matched pairs of observations. This comparison was conducted during the extremely quiescent Solar Cycle 24 minimum, so all observed differences and drifts between the two sensors are instrumental in nature. The TSIS‐1 SIM benefitted from advanced calibration capabilities based on SI standards that were not available during the preflight calibration time period of SORCE. For this reason, a revision of the SORCE SIM absolute scale is appropriate. As expected, wavelength dependent differences in absolute agreement are a function of detector sensitivity and local changes in spectral slope. At the time of the comparison SORCE SIM has been on‐orbit for 17 years while TSIS‐1 observations commenced immediately after a 100‐day outgassing and commissioning period. Peak‐to‐peak absolute scale differences are about 12% with a mean fractional difference of 0.7% ± 2.9%. The greatest scale differences occur at the change‐over between the UV and visible photodiodes in the 310 nm region, and a systematic disagreement is present in the 850–1,600 nm range. A multiplicative scale correction factor has been developed to reconcile the TSIS‐1 and SORCE difference with a wavelength dependent error on the mean typically less than 0.01% derived from every matched pair of observations. Key Points: Conduct a comparison of Solar Radiation and Climate Experiment (SORCE) and Total and Spectral Irradiance Sensor (TSIS‐1) Spectral Irradiance Monitors (SIM) over a 705‐day time periodConstruct a multiplicative correction factor that brings the SORCE SIM into agreement with the pre‐flight calibration of TSIS‐1 SIMCharacterize the uncertainties associated with the correction factor—uncertainty was two orders of magnitude less than the correction [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
23335084
Volume :
9
Issue :
3
Database :
Academic Search Index
Journal :
Earth & Space Science
Publication Type :
Academic Journal
Accession number :
156006295
Full Text :
https://doi.org/10.1029/2021EA002122