Back to Search
Start Over
Evaluating bacterial contamination of free bone fragments falling to the ground and the effectiveness of antiseptic solutions.
- Source :
-
European Journal of Orthopaedic Surgery & Traumatology . Apr2022, Vol. 32 Issue 3, p459-465. 7p. - Publication Year :
- 2022
-
Abstract
- Objectives: This study aims to determine the contamination incidence rate of bone fragments that have been dropped on the floor of the operating theatre, as well as how effective antimicrobial solutions are at decontaminating them. Methods: Bone fragments obtained after 30 total knee arthroplasties were used in the study. Inert pieces of bone emerging after the bone cuts during total knee arthroplasty were divided into 1 × 1 cm fragments. The bone fragments were first left in free fall on the floor of the operating theatre and then were kept in a number of antimicrobial solutions for 15 s. Subsequently, they were microbiologically and histopathologically examined. A swab culture was also taken from the floor of the operating theatre. Results: It was determined that 63.3% of osteochondral fragments in the non-intervened group were contaminated. Growth was likewise detected in all swab cultures. Microorganisms growing in the swab culture and the non-intervened group were similar and mostly Staphylococcus epidermidis and Klebsiella pneumoniae. When the growth rates of the 10% povidone-iodine and 4% chlorhexidine gluconate groups were compared with the growth rate of the non-intervened group, a statistical difference was found. No difference was determined between the growth rates of the sodium hypochlorite and the non-intervened groups. The histopathological analysis revealed no statistical difference between the groups in terms of bone marrow, vascular structure, fat tissue, and osteoblastic activity results in the osteochondral fragments Conclusion: Bone tissues dropped from a sterile area on the floor of the operating theatre are highly contaminated. An effective decontamination without bone cell toxicity was achieved using povidone-iodine. Although chlorhexidine gluconate solution had an effective decontamination effect compared to the non-intervened group, it was not 100% effective. Sodium hypochlorite solution was not effective in the decontamination of grafts under our working conditions. [ABSTRACT FROM AUTHOR]
- Subjects :
- *OPERATING rooms
*EXPERIMENTAL design
*KLEBSIELLA
*TOTAL knee replacement
*BACTERIAL contamination
*ONE-way analysis of variance
*FISHER exact test
*POVIDONE-iodine
*STAPHYLOCOCCUS
*CHI-squared test
*DESCRIPTIVE statistics
*STERILIZATION (Disinfection)
*CHLORHEXIDINE
*DATA analysis software
*DISINFECTION & disinfectants
*LONGITUDINAL method
*MICROBIAL sensitivity tests
Subjects
Details
- Language :
- English
- ISSN :
- 16338065
- Volume :
- 32
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- European Journal of Orthopaedic Surgery & Traumatology
- Publication Type :
- Academic Journal
- Accession number :
- 155780045
- Full Text :
- https://doi.org/10.1007/s00590-021-02978-2