Back to Search
Start Over
A Fast Low-Noise Charged-Particle CVD Diamond Detector.
- Source :
-
IEEE Transactions on Nuclear Science . Dec2004 Part 3 of 3, Vol. 51 Issue 6, p3833-3837. 5p. - Publication Year :
- 2004
-
Abstract
- This paper presents the design and test results of a charged-particle solid-state detector with ultrafast signal response based on polycrystalline chemical-vapor-deposition (pCVD) diamond as active detector material and a high-bandwidth RF amplifier. We tested the detector at the Indiana University Cyclotron Facility Bloomington, IN, in a proton beam with a kinetic energy ranging from 55 to 200 MeV. The detector signals showed an average pulsewidth of 1.38 ns, which enables single-particle counting at instantaneous rates approaching the gigahertz range. The detector operated with a signal-to-noise ratio of 7:1 for 200-MeV protons and a single-particle detection efficiency up to 99%. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00189499
- Volume :
- 51
- Issue :
- 6
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Nuclear Science
- Publication Type :
- Academic Journal
- Accession number :
- 15512986
- Full Text :
- https://doi.org/10.1109/TNS.2004.839366