Back to Search Start Over

Evaluation of Cardiac Function of Pregnant Women with High Blood Pressure during Gestation Period and Coupling of Hearts with Peripheral Vessels by Ultrasonic Cardiogram under Artificial Intelligence Algorithm.

Authors :
Zhang, Xia
Liang, Xi
Cao, Wen
Source :
Computational & Mathematical Methods in Medicine. 1/27/2022, p1-11. 11p.
Publication Year :
2022

Abstract

The research was aimed at analyzing the value of the optimized eXtreme Gradient Boosting (XGBoost) algorithm-based ultrasound cardiogram images in the diagnosis of pregnant hypertension patients. A total of 145 pregnant women (85 cases suffered from hypertension disease during pregnancy and 60 other normal women were healthy) were selected as the reference to the comparison and analysis of ultrasound cardiac function parameter, common carotid artery parameter, and the coupling relationship between hearts and cervical vessels of pregnant hypertension patients. The results demonstrated ultrasound cardiac function parameter of pregnant hypertension patients as follows. The maximum volume of the left atrium (LAVmax) was 35.65 mm, left ventricular end-systolic volume (LVESV) was 31.07 mm, and left ventricular end-diastolic volume (LVEDV) was 88.73 mm. All the above indexes were obviously higher than those of the normal control group (P < 0.05). Besides, intima-media thickness (IMT) of common carotid artery (465.84 μm), pulse wave velocity (PWV) (8.09 m/s), pressure of turning point 1 from isovolumic contraction phase to ejection phase (PT1) (126.5 mmHg), arterial enhancement pressure (AP) (6.14 mmHg), and arterial pressure enhancement index (8.58%) were all significantly higher than those of the normal control group (P < 0.05). In addition, the correlation between the coupling (E / A) of hearts and carotid artery of pregnant hypertension patients and PWV was not obvious (r = − 0.08432 , P > 0.05). The results of the research indicated that intima-media inside carotid artery of pregnant hypertension patients thickened obviously, and it became less elastic compared with that of normal healthy pregnant women. What is more, cardiac morphological changes were manifested mainly as the enlargement of the left atrial chamber and the thickening of the interventricular septum. Volume load and blood flow velocity both increased, and left ventricular diastolic function was damaged. XGBoost algorithm-based ultrasound cardiogram images could improve the diagnostic effects of hypertension during pregnancy effectively. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1748670X
Database :
Academic Search Index
Journal :
Computational & Mathematical Methods in Medicine
Publication Type :
Academic Journal
Accession number :
154922853
Full Text :
https://doi.org/10.1155/2022/5019153