Back to Search Start Over

Seismic Bearing Capacity of Geosynthetic Reinforced Strip Footings Using Upper Bound Limit Analysis.

Authors :
Rezai Soufi, Ghazal
Jamshidi Chenari, Reza
Bathurst, Richard J.
Source :
International Journal of Geomechanics. Mar2022, Vol. 22 Issue 3, p1-13. 13p.
Publication Year :
2022

Abstract

In this paper, upper bound limit analysis that includes a horizontal pseudostatic seismic force is used for the first time to obtain the limit load on strip footings seated on cohesive-frictional soils reinforced with a single geosynthetic layer. Reinforcement tensile rupture and sliding failure modes for the geosynthetic layer are included in the analyses. Results of analyses are presented as optimum reinforcement depths and a bearing capacity equation with a single term and different bearing capacity factors for tensile rupture and sliding failure modes. The bearing capacity factors are presented in tables and capture the combined influence of the reinforcement strength, soil frictional strength and cohesion, soil unit weight, footing geometry, uniform surcharge, and magnitude of horizontal ground acceleration. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15323641
Volume :
22
Issue :
3
Database :
Academic Search Index
Journal :
International Journal of Geomechanics
Publication Type :
Academic Journal
Accession number :
154712372
Full Text :
https://doi.org/10.1061/(ASCE)GM.1943-5622.0002292