PERFORMANCE EVALUATION OF A WALKING BEAM TYPE REHEATING FURNACE BASED ON ENERGY AND EXERGY ANALYSIS.

Authors :
Wenjie RONG
Baokuan LI
Fengsheng QI
Source :
Thermal Science. 2021, Vol. 25 Issue 6B, p4749-4760. 12p.
Publication Year :
2021

Abstract

A walking beam type reheating furnace with advanced control technology has been evaluated by combined energy and exergy analysis. In order to gain insight into the performance of the present furnace, the results of energy analysis are compared with those in published papers and the irreversibility of the furnace is analyzed via exergy destruction calculation. The results show that slabs preheated before charged into the furnace can save fuel and improve energy utilization. The structure and material of the wall and roof show good thermal insulation. However, the oxidized scale is a little more and the temperature of flue gas is high in the present reheating furnace. The energy efficiency of the furnace is 71.01%, while exergy efficiency is 51.41%, indicating a potential for energy-saving improvements of the present furnace. The exergy destruction of the furnace accounts for 28.36% of total exergy input which is mainly caused by heat transfer through a finite temperature difference (14.71%), fuel combustion (11.66%), and scale formation (1.99%). [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03549836
Volume :
25
Issue :
6B
Database :
Academic Search Index
Journal :
Thermal Science
Publication Type :
Academic Journal
Accession number :
154414314
Full Text :
https://doi.org/10.2298/TSCI200424226R