Effects on Lung Gas Volume, Respiratory Mechanics and Gas Exchange of a Closed-Circuit Suctioning System during Volume- and Pressure-Controlled Ventilation in ARDS Patients.

Authors :
Chiumello, Davide
Bolgiaghi, Luca
Formenti, Paolo
Pozzi, Tommaso
Lucenteforte, Manuela
Coppola, Silvia
Source :
Journal of Clinical Medicine. Dec2021, Vol. 10 Issue 23, p5657. 1p.
Publication Year :
2021

Abstract

Mechanically ventilated patients periodically require endotracheal suctioning. There are conflicting data regarding the loss of lung gas volume caused by the application of a negative pressure by closed-circuit suctioning. The aim of this study was to evaluate the effects of suctioning performed by a closed-circuit system in ARDS patients during volume- or pressure-controlled ventilation. In this prospective crossover-design study, 18 ARDS patients were ventilated under volume and pressure control applied in random order. Gas exchange, respiratory mechanics and EIT-derived end-expiratory lung volume (EELV) before the suctioning manoeuvre and after 5, 15 and 30 min were recorded. The tidal volume and respiratory rate were similar in both ventilation modes; in volume control, the EELV decreased by 31 ± 23 mL, 5 min after the suctioning, but it remained similar after 15 and 30 min; the oxygenation, PaCO2 and respiratory system elastance did not change. In the pressure control, 5 min after suctioning, EELV decreased by 35 (26–46) mL, the PaO2/FiO2 did not change, while PaCO2 increased by 5 and 30 min after suctioning (45 (40–51) vs. 48 (43–52) and 47 (42–54) mmHg, respectively). Our results suggest minimal clinical advantages when a closed system is used in volume-controlled compared to pressure-controlled ventilation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20770383
Volume :
10
Issue :
23
Database :
Academic Search Index
Journal :
Journal of Clinical Medicine
Publication Type :
Academic Journal
Accession number :
154082453
Full Text :
https://doi.org/10.3390/jcm10235657