Back to Search Start Over

Determination of a comprehensive set of drugs of abuse, metabolites and human biomarkers in wastewater using passive sampling followed by UHPLC-MS/MS analysis.

Authors :
Hahn, Roberta Zilles
Bastiani, Marcos Frank
de Lima Feltraco Lizot, Lilian
da Silva Moreira, Isabela Caroline
Meireles, Yasmin Fazenda
Schneider, Anelise
do Nascimento, Carlos Augusto
Linden, Rafael
Source :
Microchemical Journal. Jan2022:Part A, Vol. 172, pN.PAG-N.PAG. 1p.
Publication Year :
2022

Abstract

[Display omitted] • POCIS samplers were calibrated for 9 compounds related to drugs abuse consumption. • POCIS sorbent was extracted with methanol and submitted to a dual SPE clean-up. • Target compounds were sensitively measured using UHPLC-MS/MS. • First report of POCIS sampling with Oasis® HLB for cannabis metabolites. • A Brazilian wastewater treatment plant was continuously monitored for 392 days. Passive sampling of wastewater using polar organic chemical integrative samplers (POCIS) is an interesting and cost-effective strategy for the quantification of biomarkers of drugs of abuse consumption in epidemiological studies. Particularly when combined with sensitive analytical method as ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS), POCIS sampling allows the long-term and sensitive determination of a wide range of analytes. In this study, a comprehensive analytical method integrating POCIS sampling, selective solid-phase extraction (SPE) of POCIS extracts, and analysis by UHPLC-MS/MS was developed and successfully validated for 12 biomarkers of substance use, with potential use in wastewater-based epidemiology. Chromatographic separation was achieved in 11 min. The assay has a wide liner range, with lower limits of quantification of 5 ng g−1 of POCIS sorbent. The selective SPE procedure, combining both cation and anion exchange cartridges, resulted in low matrix effects (-19.3 to 22.8% for compounds with a deuterated analog internal standard and 33.4 to 42.5% for anhydroecgonine methyl ester) and high extraction yields (93.4 to 106.4%). The lab-made POCIS sampler with Oasis® HLB sorbent was adequately calibrated for 9 compounds (4 drugs of abuse, 4 drug metabolites, and 1 human non-drug lifestyle markers). The method was applied in a wastewater treatment plant in Brazil, with continuous monitoring for 392 days in 2020–2021. The highest calculated wastewater concentration among drugs of abuse and metabolites was found for benzoylecgonine (431.5 ± 190.6 ng L-1), followed by 11-nor-9-carboxy-Δ9-THC (58.3 ± 21.1 ng L-1). The assay described in this study can be used as an effective tool to monitor the presence of relevant drug consumption biomarkers in wastewater, a relevant epidemiologic strategy currently limited due to the sophisticated infrastructure needed for representative sampling. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0026265X
Volume :
172
Database :
Academic Search Index
Journal :
Microchemical Journal
Publication Type :
Academic Journal
Accession number :
153902724
Full Text :
https://doi.org/10.1016/j.microc.2021.106960