Back to Search Start Over

Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography.

Authors :
Lever, Mael
Halfwassen, Christian
Unterlauft, Jan Darius
Bechrakis, Nikolaos E.
Manthey, Anke
Böhm, Michael R. R.
Source :
Graefe's Archive of Clinical & Experimental Ophthalmology. Dec2021, Vol. 259 Issue 12, p3777-3786. 10p.
Publication Year :
2021

Abstract

Purpose: A central diagnostic tool in adult glaucoma is the peripapillary retinal nerve fibre layer (pRNFL) thickness. It can be assessed by scanning laser polarimetry (SLP) or optical coherence tomography (OCT). However, studies investigating the relevance of pRNFL measurements in children are rare. This study aims to compare the glaucoma diagnosing ability of SLP and OCT pRNFL thickness measurements in a paediatric population. Methods: This retrospective study included 105 children (glaucoma: 22 (21.0%); healthy glaucoma suspects: 83 (79.0%)) aged 4–18 years, examined with SLP (GDxPro/ECC, Carl Zeiss Meditec) and spectral-domain OCT (SPECTRALIS®, Heidelberg Engineering). The thickness of pRNFL sectors was compared between diseased and healthy participants. Areas under the receiver-operating characteristic curves (AUC) and logistic regression results were used to compare the glaucoma discriminative capacity between SLP and OCT measurements. Results: Using OCT, pRNFL thickness was decreased in the superior, nasal, and inferior quadrants of glaucoma patients compared to healthy controls (P < 0.001, each). With SLP, such a difference was only observed in the inferior quadrant (P = 0.011). A correlation between glaucoma diagnosis and OCT-measured pRNFL thickness was found in all quadrants (P < 0.001) other than the temporal. With SLP, a correlation was found for the total average thickness (P = 0.037) and inferior quadrant (P = 0.0019). Finally, the AUCs of OCT measurements were markedly higher than those of SLP (e.g., inferior quadrant: OCT 0.83, SLP 0.68). Conclusion: pRNFL thickness measurements using both OCT and SLP, correlate notably with the presence of glaucoma. In general, the diagnostic performance of pRNFL thickness measurements seems higher for OCT than for SLP. Thus, pRNFL thickness measurements could provide important information, complementing conventional clinical and functional parameters in the diagnostic process of paediatric glaucoma. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0721832X
Volume :
259
Issue :
12
Database :
Academic Search Index
Journal :
Graefe's Archive of Clinical & Experimental Ophthalmology
Publication Type :
Academic Journal
Accession number :
153556074
Full Text :
https://doi.org/10.1007/s00417-021-05276-z