- Fire resistance of walls made of sandwich panels with mineral wool core – experimental verification of the extrapolation rules in DIN EN 15254‐5 for the fire resistance of walls made of sandwich panels Sandwich panels fulfil different requirements under fire load depending on their composition. For the selection and application, a classification of the fire behaviour and the fire resistance class is required. Since the classification cannot be investigated for all applications, verified extrapolation rules are required to provide a classification based on the building application. As part of a research program which was conducted by the Versuchsanstalt für Stahl, Holz und Steine of the KIT, walls made of sandwich panels with a mineral wool core were tested and the test results were compared with the extrapolation rules of DIN EN 15254‐5 and suggestions for extrapolation based on the test results were developed. [ABSTRACT FROM AUTHOR]