Back to Search
Start Over
Effect of ECG-gating Retinal Photographs on Retinal Vessel Caliber Measurements in Subjects with and without Type 2 Diabetes.
- Source :
-
Current Eye Research . November 2021, Vol. 46 Issue 11, p1742-1750. 9p. - Publication Year :
- 2021
-
Abstract
- Purpose/Aim of this study: Retinal vessel caliber is an independent risk marker of cardiovascular disease risk. However, variable mechanical delays in capturing retinal photographs and cardiac cycle-induced retinal vascular changes have been shown to reduce the accuracy of retinal vessel caliber measurements, but this has only ever been investigated in healthy subjects. This cross-sectional study is the first study to investigate this issue in type 2 diabetes. The aim of this study was to determine whether ECG-gating retinal photographs reduce the variability in retinal arteriolar and venular caliber measurements in controls and type 2 diabetes. Materials and Methods: Fifteen controls and 15 patients with type 2 diabetes were arbitrarily recruited from Westmead Hospital, Sydney, Australia. A mydriatic fundoscope connected to our novel ECG synchronization unit captured 10 ECG-gated (at the QRS) and 10 ungated digital retinal photographs of the left eye in a randomized fashion, blinded to study participants. Two independent reviewers used an in-house semi-automated software to grade single cross-sectional vessel diameters across photographs, between 900 and 1800 microns from the optic disc edge. The coefficient of variation compared caliber variability between retinal arterioles and venules. Results: Our ECG synchronization unit reported the smallest time delay (33.1 ± 48.4 ms) in image capture known in the literature. All 30 participants demonstrated a higher reduction in retinal arteriolar (ungated: 1.02, 95%CI 0.88–1.17% vs ECG-gated: 0.39, 95%CI 0.29–0.49%, p <.0001) than venular (ungated 0.62, 95%CI 0.53–0.73% vs ECG-gated: 0.26, 95%CI 0.19–0.35%, p <.0001) coefficient of variation by ECG-gating photographs. Intra-observer repeatability and inter-observer reproducibility analysis reported high interclass correlation coefficients ranging from 0.80 to 0.86 and 0.80 to 0.93 respectively. Conclusion: ECG-gating photographs at the QRS are recommended for retinal vessel caliber analysis in controls and patients with type 2 diabetes as they refine measurements. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02713683
- Volume :
- 46
- Issue :
- 11
- Database :
- Academic Search Index
- Journal :
- Current Eye Research
- Publication Type :
- Academic Journal
- Accession number :
- 152820070
- Full Text :
- https://doi.org/10.1080/02713683.2021.1927112