Back to Search Start Over

Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code.

Authors :
Yahya, M. F. O.
Kocak, F.
Source :
Advances in High Energy Physics. 9/15/2021, p1-5. 5p.
Publication Year :
2021

Abstract

LYSO scintillation crystals, due to their significant characteristics such as high light yield, fast decay time, small Moliére radius, and good radiation hardness, are proposed to be used for the electromagnetic calorimeter section of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this work, the center of gravity technique was used to determine the impact coordinates of an electron initiating an electromagnetic shower in a LYSO array, in a calorimeter module containing nine crystals, each 25 mm × 25 mm in cross-section and 200 mm in length. The response of the calorimeter module has been studied with electrons having energies in the range 0.1 GeV-2 GeV. By using the Monte Carlo simulation based on Geant4, the two-dimensional position resolution of the module is obtained as σ R mm = 3.95 ± 0.08 / E ⊕ 1.91 ± 0.11 at the center of the crystal. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16877357
Database :
Academic Search Index
Journal :
Advances in High Energy Physics
Publication Type :
Academic Journal
Accession number :
152466507
Full Text :
https://doi.org/10.1155/2021/9931708