Back to Search Start Over

Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: effective and durable!

Authors :
Carino, Davide
Zancanaro, Edoardo
Lapenna, Elisabetta
Ruggeri, Stefania
Denti, Paolo
Iaci, Giuseppe
Buzzatti, Nicola
Calabrese, Maria Chiara
Nascimbene, Simona
Sala, Alessandra
Castiglioni, Alessandro
Alfieri, Ottavio
Bonis, Michele De
Source :
European Journal of Cardio-Thoracic Surgery. Jul2021, Vol. 60 Issue 1, p115-121. 7p.
Publication Year :
2021

Abstract

Open in new tab Download slide Open in new tab Download slide OBJECTIVES 3-Dimensional (3D)-shaped rings are largely adopted for tricuspid annuloplasty, but evidence about their long-term results is scanty. The goal of this study was to analyse the long-term results of tricuspid annuloplasty with 3D-shaped rings. MATERIALS AND METHODS A retrospective review of our prospectively maintained database was carried out to identify all patients who underwent tricuspid valve repair with 3D-shaped rings between January 2011 and December 2014. Kaplan–Meier methods were used to analyse long-term survival. Cumulative incidence function using death as the competitive outcome was used to estimate cardiac death. RESULTS A total of 168 patients were identified. The median age was 66 years. Eighty-two patients (49%) were in advanced New York Heart Association functional class III–IV. Atrial fibrillation (AF) was present in 101 (60%); the median ejection fraction was 60%. In 82 (49%) patients, a Medtronic 3D Contour annuloplasty ring was employed; in the remaining 86 (51%) patients, an Edwards MC3 ring was used. Cumulative incidence function of cardiac death, with non-cardiac death as a competing risk, was 1.9 ± 1.1%, 95% confidence interval (CI) (0.51–4.95) at 7 years. The cumulative incidence function of recurrence of tricuspid regurgitation (TR) ≥2+ at 7 years was 14 ± 3.17%, 95% CI (8.49–20.82). Recurrence of TR ≥2+ at 7 years was not significantly different between the Medtronic 3D Contour and the Edwards MC3 rings (P  = 0.3). AF was identified as the only independent predictor of recurrence of TR ≥2+. CONCLUSIONS 3D-shaped rings are effective and durable. TR recurrence was relatively low at 7 years and usually moderate (2+/4+) without a significant difference between the 2 types of rings. The role of AF as a predictor of TR recurrence was confirmed. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10107940
Volume :
60
Issue :
1
Database :
Academic Search Index
Journal :
European Journal of Cardio-Thoracic Surgery
Publication Type :
Academic Journal
Accession number :
152291405
Full Text :
https://doi.org/10.1093/ejcts/ezab111