Back to Search Start Over

Multicentric evaluation of BioFire FilmArray Pneumonia Panel for rapid bacteriological documentation of pneumonia.

Authors :
Gastli, Nabil
Loubinoux, Julien
Daragon, Matthieu
Lavigne, Jean-Philippe
Saint-Sardos, Pierre
Pailhoriès, Hélène
Lemarié, Carole
Benmansour, Hanaa
d'Humières, Camille
Broutin, Lauranne
Dauwalder, Olivier
Levy, Michael
Auger, Gabriel
Kernéis, Solen
Cattoir, Vincent
Source :
Clinical Microbiology & Infection. Sep2021, Vol. 27 Issue 9, p1308-1314. 7p.
Publication Year :
2021

Abstract

To evaluate performances of the rapid multiplex PCR assay BioFire FilmArray Pneumonia Panel (FA-PP) for detection of bacterial pathogens and antibiotic resistance genes in sputum, endotracheal aspirate (ETA) and bronchoalveolar lavage (BAL) specimens. This prospective observational study was conducted in 11 French university hospitals (July to December 2018) and assessed performance of FA-PP by comparison with routine conventional methods. A total of 515 respiratory specimens were studied, including 58 sputa, 217 ETA and 240 BAL. The FA-PP detected at least one pathogen in 384 specimens, yielding an overall positivity rate of 74.6% (384/515). Of them, 353 (68.5%) specimens were positive for typical bacteria while eight atypical bacteria and 42 resistance genes were found. While identifying most bacterial pathogens isolated by culture (374/396, 94.4%), the FA-PP detected 294 additional species in 37.7% (194/515) of specimens. The FA-PP demonstrated positive percentage agreement and negative percentage agreement values of 94.4% (95% CI 91.7%–96.5%) and 96.0% (95% CI 95.5%–96.4%), respectively, when compared with culture. Of FA-PP false-negative results, 67.6% (46/68) corresponded to bacterial species not included in the panel. At the same semi-quantification level (in DNA copies/mL for FA-PP versus in CFU/mL for culture), the concordance rate was 43.4% (142/327) for culture-positive specimens with FA-PP reporting higher semi-quantification of ≥1 log 10 in 48.6% (159/327) of cases. Interestingly, 90.1% of detected bacteria with ≥106 DNA copies/mL grew significantly in culture. FA-PP is a simple and rapid molecular test that could complement routine conventional methods for improvement of diagnosis accuracy of pneumonia. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1198743X
Volume :
27
Issue :
9
Database :
Academic Search Index
Journal :
Clinical Microbiology & Infection
Publication Type :
Academic Journal
Accession number :
152188945
Full Text :
https://doi.org/10.1016/j.cmi.2020.11.014