Abstract
- <bold>Purpose: </bold>To compare liver stiffness (LS) in patients with suspected diffuse liver disease between gradient-recalled-echo magnetic resonance elastography (GRE-MRE) and different spin-echo echo-planar imaging (SE-EPI-MRE) sequences and to investigate confounding factors including fat, iron, age, and sex.<bold>Method: </bold>LS was measured at 1.5T using GRE-MRE, SE-EPI-MRE and short-TE-SE-EPI-MRE (hiSE-EPI-MRE) sequences and compared using Bland-Altman-plots together with concordance correlation coefficients (CCC). Success gradings were evaluated considering possible confounding factors.<bold>Results: </bold>305 patients (225 male, 80 females, mean age 51.12 years) were included. 109/305 showed hepatic iron overload, 183 hepatic steatosis. The mean difference (bias) in stiffness values between GRE-MRE and SE-EPI-MRE/hiSE-EPI-MRE was 0.15/0.2 kPa (LOA: -0.72,0.41 kPa/-0.94,0.55 kPa), between SE-EPI-MRE and hiSE-EPI-MRE 0.04 kPa (LOA: -0.62,0.53 kPa). The CCC for agreement between stiffness values for GRE-MRE and SE-EPI-MRE was 0.94 (0.92-0.95), 0.89 (0.86-0.91) for hiSE-EPI-MRE and GRE-MRE and 0.94 (0.92-0.95) for SE-EPI-MRE and hiSE-EPI-MRE. Using GRE-MRE, 72/305 showed unusable results whereby all these patients had high iron levels (mean R2*=209.7 1/s). For SE-EPI-MRE and hiSE-EPI-MRE only 10/305 and 8/305 were inconclusive respectively, corresponding to a significantly higher iron load (mean R2*= 549.2 1/s for SE-EPI-MRE and 570.7 1/s for hiSE-EPI-MRE). Concerning fat, age or sex no significant influence on success was observed for all sequences.<bold>Conclusions: </bold>Good agreement of LS values was observed between GRE-MRE and SE-EPI-MRE sequences. The number of successful exams, however, was considerably lower for GRE-MRE, mainly due to iron content. Study reference number: AN5093. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0720048X
- Volume :
- 142
- Database :
- Academic Search Index
- Journal :
- European Journal of Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 152003358
- Full Text :
- https://doi.org/10.1016/j.ejrad.2021.109898