Spectral resolution and speech perception after cochlear implantation using the round window versus cochleostomy technique.

Authors :
Demir, B
Yüksel, M
Atılgan, A
Ciprut, A
Batman, C
Source :
Journal of Laryngology & Otology. Jun2021, Vol. 135 Issue 6, p513-517. 5p.
Publication Year :
2021

Abstract

Objective: To evaluate the spectral resolution achieved with a cochlear implant in users who were implanted using round window route electrode insertion versus a traditional cochleostomy technique. Methods: Twenty-six patients were classified into two groups according to the surgical approach: one group (n = 13) underwent cochlear implantation via the round window technique and the other group (n = 13) underwent surgery via cochleostomy. Results: A statistically significant difference was found in spectral ripple discrimination scores between the round window and cochleostomy groups. The round window group performed almost two times better than the cochleostomy group. Differences between Turkish matrix sentence test scores were not statistically significant. Conclusion: The spectral ripple discrimination scores of patients who had undergone round window cochlear implant electrode insertion were superior to those of patients whose cochlear implants were inserted using a classical cochleostomy technique. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00222151
Volume :
135
Issue :
6
Database :
Academic Search Index
Journal :
Journal of Laryngology & Otology
Publication Type :
Academic Journal
Accession number :
151399147
Full Text :
https://doi.org/10.1017/S0022215121001183