Back to Search Start Over

Toward PET/MRI as one-stop shop for radiotherapy planning in cervical cancer patients.

Authors :
Ahangari, Sahar
Hansen, Naja Liv
Olin, Anders Beck
Nøttrup, Trine Jakobi
Ryssel, Heidi
Berthelsen, Anne Kiil
Löfgren, Johan
Loft, Annika
Vogelius, Ivan Richter
Schnack, Tine
Jakoby, Bjoern
Kjaer, Andreas
Andersen, Flemming Littrup
Fischer, Barbara Malene
Hansen, Adam Espe
Source :
Acta Oncologica. Aug2021, Vol. 60 Issue 8, p1045-1053. 9p. 2 Color Photographs, 1 Black and White Photograph, 1 Chart, 1 Graph.
Publication Year :
2021

Abstract

Radiotherapy (RT) planning for cervical cancer patients entails the acquisition of both Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). Further, molecular imaging by Positron Emission Tomography (PET) could contribute to target volume delineation as well as treatment response monitoring. The objective of this study was to investigate the feasibility of a PET/MRI-only RT planning workflow of patients with cervical cancer. This includes attenuation correction (AC) of MRI hardware and dedicated positioning equipment as well as evaluating MRI-derived synthetic CT (sCT) of the pelvic region for positioning verification and dose calculation to enable a PET/MRI-only setup. 16 patients underwent PET/MRI using a dedicated RT setup after the routine CT (or PET/CT), including eight pilot patients and eight cervical cancer patients who were subsequently referred for RT. Data from 18 patients with gynecological cancer were added for training a deep convolutional neural network to generate sCT from Dixon MRI. The mean absolute difference between the dose distributions calculated on sCT and a reference CT was measured in the RT target volume and organs at risk. PET AC by sCT and a reference CT were compared in the tumor volume. All patients completed the examination. sCT was inferred for each patient in less than 5 s. The dosimetric analysis of the sCT-based dose planning showed a mean absolute error (MAE) of 0.17 ± 0.12 Gy inside the planning target volumes (PTV). PET images reconstructed with sCT and CT had no significant difference in quantification for all patients. These results suggest that multiparametric PET/MRI can be successfully integrated as a one-stop-shop in the RT workflow of patients with cervical cancer. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0284186X
Volume :
60
Issue :
8
Database :
Academic Search Index
Journal :
Acta Oncologica
Publication Type :
Academic Journal
Accession number :
151347918
Full Text :
https://doi.org/10.1080/0284186X.2021.1936164