Back to Search Start Over

Contrast agent dose reduction in computed tomography with deep learning using a conditional generative adversarial network.

Authors :
Haubold, Johannes
Hosch, René
Umutlu, Lale
Wetter, Axel
Haubold, Patrizia
Radbruch, Alexander
Forsting, Michael
Nensa, Felix
Koitka, Sven
Source :
European Radiology. Aug2021, Vol. 31 Issue 8, p6087-6095. 9p.
Publication Year :
2021

Abstract

Objectives: To reduce the dose of intravenous iodine-based contrast media (ICM) in CT through virtual contrast-enhanced images using generative adversarial networks. Methods: Dual-energy CTs in the arterial phase of 85 patients were randomly split into an 80/20 train/test collective. Four different generative adversarial networks (GANs) based on image pairs, which comprised one image with virtually reduced ICM and the original full ICM CT slice, were trained, testing two input formats (2D and 2.5D) and two reduced ICM dose levels (−50% and −80%). The amount of intravenous ICM was reduced by creating virtual non-contrast series using dual-energy and adding the corresponding percentage of the iodine map. The evaluation was based on different scores (L1 loss, SSIM, PSNR, FID), which evaluate the image quality and similarity. Additionally, a visual Turing test (VTT) with three radiologists was used to assess the similarity and pathological consistency. Results: The −80% models reach an SSIM of > 98%, PSNR of > 48, L1 of between 7.5 and 8, and an FID of between 1.6 and 1.7. In comparison, the −50% models reach a SSIM of > 99%, PSNR of > 51, L1 of between 6.0 and 6.1, and an FID between 0.8 and 0.95. For the crucial question of pathological consistency, only the 50% ICM reduction networks achieved 100% consistency, which is required for clinical use. Conclusions: The required amount of ICM for CT can be reduced by 50% while maintaining image quality and diagnostic accuracy using GANs. Further phantom studies and animal experiments are required to confirm these initial results. Key Points: • The amount of contrast media required for CT can be reduced by 50% using generative adversarial networks. • Not only the image quality but especially the pathological consistency must be evaluated to assess safety. • A too pronounced contrast media reduction could influence the pathological consistency in our collective at 80%. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09387994
Volume :
31
Issue :
8
Database :
Academic Search Index
Journal :
European Radiology
Publication Type :
Academic Journal
Accession number :
151332912
Full Text :
https://doi.org/10.1007/s00330-021-07714-2