Back to Search Start Over

Deep Learning-Based Computed Tomography Perfusion Mapping (DL-CTPM) for Pulmonary CT-to-Perfusion Translation.

Authors :
Ren, Ge
Zhang, Jiang
Li, Tian
Xiao, Haonan
Cheung, Lai Yin
Ho, Wai Yin
Qin, Jing
Cai, Jing
Xiao, Hao Nan
Yin Cheung, Andy Lai
Source :
International Journal of Radiation Oncology, Biology, Physics. Aug2021, Vol. 110 Issue 5, p1508-1518. 11p.
Publication Year :
2021

Abstract

<bold>Purpose: </bold>Our purpose was to develop a deep learning-based computed tomography (CT) perfusion mapping (DL-CTPM) method that synthesizes lung perfusion images from CT images.<bold>Methods and Materials: </bold>This paper presents a retrospective analysis of the pulmonary technetium-99m-labeled macroaggregated albumin single-photon emission CT (SPECT)/CT scans obtained from 73 patients at Queen Mary Hospital in Hong Kong in 2019. The left and right lung scans were separated to double the size of the data set to 146. A 3-dimensional attention residual neural network was constructed to extract textural features from the CT images and reconstruct corresponding functional images. Eighty-four samples were randomly selected for training and cross-validation, and the remaining 62 were used for model testing in terms of voxel-wise agreement and function-wise concordance. To assess the voxel-wise agreement, the Spearman's correlation coefficient (R) and structural similarity index measure between the images predicted by the DL-CTPM and the corresponding SPECT perfusion images were computed to assess the statistical and perceptual image similarities, respectively. To assess the function-wise concordance, the Dice similarity coefficient (DSC) was computed to determine the similarity of the low/high functional lung volumes.<bold>Results: </bold>The evaluation of the voxel-wise agreement showed a moderate-to-high voxel value correlation (0.6733 ± 0.1728) and high structural similarity (0.7635 ± 0.0697) between the SPECT and DL-CTPM predicted perfusions. The evaluation of the function-wise concordance obtained an average DSC value of 0.8183 ± 0.0752 for high-functional lungs (range, 0.5819-0.9255) and 0.6501 ± 0.1061 for low-functional lungs (range, 0.2405-0.8212). Ninety-four percent of the test cases demonstrated high concordance (DSC >0.7) between the high-functional volumes contoured from the predicted and ground-truth perfusions.<bold>Conclusions: </bold>We developed a novel DL-CTPM method for estimating perfusion-based lung functional images from the CT domain using a 3-dimensional attention residual neural network, which yielded moderate-to-high voxel-wise approximations of lung perfusion. To further contextualize these results toward future clinical application, a multi-institutional large-cohort study is warranted. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03603016
Volume :
110
Issue :
5
Database :
Academic Search Index
Journal :
International Journal of Radiation Oncology, Biology, Physics
Publication Type :
Academic Journal
Accession number :
151306995
Full Text :
https://doi.org/10.1016/j.ijrobp.2021.02.032